30
6.2018
4.
* * appear along the chosen parameter.
The
keys
and
change the value of the
parameter
Normal
. This way you raise or lower
the maximum temperature of heating water at
outside temperature of -18 °C. To confirm the
settings press key
(ENTER).
The recommended values of the maximum
temperature for individual types of heating are
given in chapter 5.1.
5.
After confirming the settings the controller
calculates the new temperature setting of the
heating water according to outside temperature
(heating curve); if the outside temperature is
higher than
-18 °C, this calculated temperature lower than
the set temperature.
For returning to the basic view press the key
(MENU) twice.
Repeat the process for each circuit.
NOTE
For economical and comfortable use of heating we recommend the use of
heating curve heating
.
For heating curve heating, you can choose various temperature modes of
operation with setting daily and weekly schedules. See chapter 5.4.
5.1.3 Heating based on constant temperature
For ensuring economical operation of the whole system we recommend choosing heating curve of
heating. Nevertheless, if you want to heat the rooms with constant water temperature in the system,
we recommend the following settings:
TYPE
OF
HOUSE
PARAMETER
HEATING (with constant temperature)
Heating, 1. Circuit, 2. Circuit, 3.
Circuit, and 4. Circuit
Floor, wall [°C]
Convector
heating [°C]
Radiation
heating 55 °C
Radiation
heating 65
°C
Non-insulated
house
Normal
38
50
50
55
Standby
3
5
5
7
Insulated house
Normal
35
45
47
50
Standby
2
5
5
6
Well-insulated
house
Normal
30
40
45
47
Standby
2
5
5
5
NOTE
In
mixing heating circuits
we adjust the adjustable temperature of the
supply pipe;
in
direct heating circuits
and on the device we adjust the temperature of the
return
.
C/W I
Schedule
*Normal 45.0°C *
Eco -2.0°C
C/W I
Schedule
>Normal
45°C <
Eco
-2.0°C