50
6.2018
8 Information display of operation
The controller interface TERMOTRONIC
displays information about the device on its main display
at any time. The information needed by the user is described in
Line 1
and
Line 2
.
The information
needed by the installer is displayed in the
DIAGNOSTICS DISPLAY
described in chapter 8.1.
NOTE
Depending on the type of installed device, the TERMOTRONIC controller display shows
various conditions of the device.
The following information is displayed in
Line 1
:
Line 1
Description
HP STOP.............
The operation of the device is shut down (including circuit
control).
ERROR **NO
WATER*
There was a switch of the heat source pump or shortage of
water for the heat source
HpDHW
Alarm; the pressure in the cooling system was too high during heating
DHW.
HpHeat
Alarm; the pressure in the cooling system was too high during heating.
.
HpCool
Alarm; the pressure in the cooling system was too high during cooling.
LpDHW
Alarm; the pressure in the cooling system was too low during heating
DHW.
LpHea
Alarm; the pressure in the cooling system was too low during heating.
LpCol
Alarm; the pressure in the cooling system was too low during cooling.
Tz
Alarm; there was overvoltage, under voltage or inverted phase
sequence in the electrical grid.
DHW.................
The device heats DHW.
Screed drying.......
The programme for drying screeds is activated.
Heating.............
The device operates in the heating mode (only in winter mode).
Cooling.............
The device operates in the cooling mode (only in summer
mode).
DHW + Add.source
The device (HP – compressor) operates simultaneously with
additional heat source (the compressor and additional source
simultaneously). Switching on the additional source is described
in the section 4.6.
ScAdd.source
Heating + DHW
The device operates in the heating mode parallel to the electric
heater which is installed into the DHW for heating DHW.
H Add.source
The device (HP – compressor) operates simultaneously with
additional heat source (the compressor and additional source
simultaneously). Switching on the additional source is described
in the section 4.6.
Cooling + DHW
The device operates in the cooling mode parallel to heating of
DHW.
SwimmingPoolHeating
The device operates in the swimming pool heating mode.
Heating-Res.source..
Line 1
Line 2
Return
32.3°C
DHW
49.0°C