20
6.2018
4.4 Changing the operational mode - winter/summer mode
The
mode
of operation -
winter
or
summer
, is chosen according to season. In the time when you
do not need heating or want to cool the rooms, switch to
summer
operating mode. In case heating
is needed, switch to
winter
mode. The choice can be automatic or manual.
NOTE
If you do not switch into the summer mode operation in the summer, this can result in
higher energy consumption. The operational costs will be increased for two reasons:
The main circulation pump will switch on from time to time to check whether
the need for heating has arisen.
The additional source could also be turned on (for the protection of the heating
system) if the temperature falls below a certain point, i.e. 12 °C – this depends
on the start-up settings.
NOTE
The cooling function is only provided by reversible and WPG + passive models of the
devices.
The function of the
device according to
the chosen mode of
operation:
Mode
OPERATION
Heating
DHW
Cooling
Winter
YES
YES
NO
Summer
NO
YES
YES
NOTE
In the
winter
mode (heating and DHW) the heating system works only for heating the
heating water of activated circles and DHW. By using the built-in external switch we
can launch manual switch on/off of the cooling mode of the device.
4.4.1 Changing the operating mode
Changing the operation from winter to summer mode is performed in the following steps:
1.
Press key
(MENU) in the basic menu.
2.
In the user interface, use the key
and
choose menu
Mode
.
3.
To choose the menu
Mode
press key
(ENTER).
Standby…………………………….
Heating
35.5°C
Return
32.3°C
DHW
49.0°C
> Heating
<
1. Circuit
2. Circuit
3. Circuit
>
Mode
<
Temperatures