22
6.2018
2.
Choose the menu
Cooling
or use the key
to choose the desired
Circuit
in the first menu.
To set the parameter press key
(ENTER).
3.
In the menu
Cooling
(or
Circuit
) use the key
to choose the parameter
Normal
and
press the key
(ENTER).
4.
* * appear along the chosen parameter.
Use
the key
or
to change the value of the
parameter
Normal
; by doing so you raise or
lower the temperature of the accumulator (or
circuit).
To confirm the settings press key
(ENTER).
5.
For returning to the basic view press the key
(MENU) twice.
NOTE
The cooling and individual circuits settings are separated from the heating, this
is why all settings for cooling remain unchanged with the change of the mode
into heating.
In the case of floor, ceiling or wall cooling appropriate settings and protection
have to be ensured in order not to cause surface condensation.
For controlling the temperature settings of cooling water you can set different
temperature modes, daily and weekly schedules. See chapter 5.4.
The response of the cooling system in convector cooling is faster than in floor,
ceiling or wall cooling.
4.6 Switching on the additional heat source
In case the heating capacity of the device is not sufficient for covering thermal losses of the building
under given weather conditions, you can increase the capacity by switching on the
Additional
source
.
The device has a Backup source, a flow electric water heater fitted as standard which can function
as an additional heat source by activating the parameter
Additional source
. Basically, the
controller is set to activate the additional source which operates parallel to the device if the external
air temperature falls below -7 °C. This setting is set according to the building at commissioning and
can be changed later. Before setting the parameter we advise consulting the contractor for
commissioning.
NOTE
In case you would like to use an oil/gas/pellet furnace or external electric heater as
auxiliary heat source, you have to ask the contractor for commissioning to perform the
setting.
Activating the additional source manually is performed in the following steps:
>
Cooling
<
1. Circuit
2. Circuit
3. Circuit
Schedule
>Normal
13.0°C <
Eco
-2.0°C
Comfort
0.0°C
-2.0°C
Schedule
*Normal 12.5°C *
Eco -2.0°C
Comfort
0.0°C
Schedule
>Normal
12.5°C <
Eco
-2.0°C
Comfort
0.0°C
Содержание WPG 30
Страница 62: ...62 6 2018 ...
Страница 63: ...6 2018 63 ...