28
6.2018
The weather controlled heating curve shows that the temperature of the return (heating water
returning to the heat pump from heating bodies) depends on the temperature of air outside the
building. The lower the external air temperature, the higher the calculated needed temperature of
the return.
The weather controlled heating curve
The appropriate heating temperature setting is essential for ensuring the desired comfort. It
depends on the characteristics of the house and heating bodies as well as the project temperature.
The table below lists the recommended settings which can help you decide on the appropriate
parameters of the weather controlled heating.
TYPE
OF
HOUSE
PARAMETER
HEATING (weather controlled)
Heating, 1. Circuit, 2. Circuit, 3. Circuit,
and 4. Circuit
Floor,
wall [°C]
Convector
heating
[°C]
Radiation
heating 55 °C
Radiation
heating 65 °C
Non-
insulated
house
Normal
-
55
65
70
Standby
-3
5
5
7
Correction - Correction of breaking point
(+15 °C)
-
10
13
15
Insulated
house
Normal
35
50
55
65
Standby
2
5
5
6
Correction - Correction of breaking point
(+15 °C)
5
5
10
12
Well-
insulated
house
Normal
30
40
55
55
Standby, Hysteresis
2
5
5
5
Correction - Correction of breaking point
(+15 °C)
3
3
5
10
NOTE
In
mixing heating circuits
we adjust the adjustable temperature of the
supply pipe;
in
direct heating circuits
and on the device we adjust the temperature of the
return
.
20
25
30
35
40
45
50
55
-18
-13
-8
-3
2
7
12
17
22
T
e
m
p
e
ra
tu
re
o
f
h
e
a
ti
n
g
w
a
te
r
[°
C
]
Temperature of external air [°C]
Setting of weather
controlled heating
Normal
Setting of breaking point for
the weather guided heating
- transitional period
Correction
The calculated temperature of the
return setting at current temperature
of external air
.
15