70
CMC TECHNICAL REFERENCE MANUAL
1X36003 Version 2.52
1996-1999 Ingersoll-Rand Company
Date of Issue: 18-Oct-1999
Controller Problems
Description:
The CMC System is generally comprised of a Base Control Module (BCM), Operator User
Interface (OUI), and Power Supply (PS). There are few user serviceable components within
the system, however, a brief understanding of the system will help in overall troubleshooting.
All components require 24 VDC and rely on hardware and software to perform correctly, if
the problem cannot be isolated to a power problem it is most likely a hardware or software
problem, which will require Ingersoll-Rand support to correct.
Component Specification:
•
VDC power required
•
Software required
Troubleshooting:
The following table identifies typical problems, probable causes, and appropriate procedures
for verifying the probable cause:
Typical Problem
Probable Cause
Troubleshooting
Procedure
BCM fault suspected
No power
CMCS #4
OUI is dim
Wrong contrast selected
CMCS #1
Backlight failing
CMCS #1
OUI is black
No power
CMCS #2
OUI displays “
INGERSOLL-RAND
Centrifugal Compressor Division”
Cable disconnected
CMCS #3
OUI displays “Status XXH”
Where XX is a specific number
Many
Refer to Status Codes
under System Information
Section.
MODBUS communications problem No power
CMCS #5
Many
Refer to the UCM Section.