SYSTEM
SETTINGS
INFO
Loaded
Remote
Load Selected
Power On Hours 12338
Running Hours 11445
Loaded Hours 11223
BCM Ver: 2.52
Number of Starts 35
Info Folder - Page 3: Hour Meters and Version
Edit-
x
Time
The Time value has been edited from location
x
.
Edit-
x
Year
The Year value for the Date field has been edited from location
x
.
E-Stop pressed
Emergency Stop push button has been pressed.
Load (
Location
)
A Load command has been issued from network communications.
Loss of Motor Current
Motor current feedback was lost while running.
MinLoad Clamped
The MinLoad Control or User Setpoint value has been limited to the MaxLoad Setpoint value.
MinLoad Incremented
The MinLoad Control Setpoint value has been incremented as a result of surge.
MinLoad Reset
The MinLoad Control Setpoint value has been reset to the MinLoad User Setpoint value.
Starting Fail
Driver feedback was not received after a Start command was issued.
Starter Failure
Feedback was not received from the starter after a Start command was issued.
Power Down
The Base Control Module (BCM) was de-energized.
Power Up
The Base Control Module (BCM) was energized.
Reset (
Location
)
A Reset command has been issued from
Location
.
Start (
Location
)
A Start command has been issued from
Location
.
Starter Failure
Starter feedback was not received after a Start command was issued.
Stop (
Location
)
A Stop command has been issued from
Location
.
Surge
The controller has detected a Surge.
Surge Unload Alarm
The alarm condition when the compressor has unloaded as a result of multiple surges.
Unload (
Location
)
An Unload command has been issued from
Location
.
NOTE 1
: “
Location
” is replaced by “Comm” for communications network, “Local” for local compressor display and “Remote”
for hardwired remote communications.
NOTE 2
: “
x
” is replaced by “C” for edits from a communication network and “L” for edits from the local display.
NOTE 3
: All Analog Inputs get edit local, edit communications, alarm and trip event messages.
NOTE 4
: All Discrete Inputs for Alarm or Trip get alarm and trip event messages.
This last INFO Folder page
shows the hour meters and
number of starts. Power On
Hours is the time that the panel
power has been on. The Running
Hours is the amount of time that
the compressor has been
operating between each start and
stop sequence. The Loaded
Hours is the amount of time that
the compressor has been running
and not running unloaded. It can
also be defined as the number of
hours that the inlet valve is not in
the Inlet Unload Position. The Number of (Compressor) Starts is self-explanatory.
NOTE
Most electric motors are only rated for two cold starts or one hot start per hour. It is
the operator’s responsibility not to exceed the electric motor’s limitation. The control
system allows the compressor to be started when the compressor is ready, not the
motor.