24
CMC TECHNICAL REFERENCE MANUAL
1X36003 Version 2.52
1996-1999 Ingersoll-Rand Company
Date of Issue: 18-Oct-1999
INFO Folder
SETTINGS Folder
Navigation and
Enter Keys
NAVIGATION MODE
Navigation mode is active when a folder name (SYSTEM,
INFO or SETTINGS) is highlighted. When inactive, press the
ENTER key to activate.
FOLDER NAVIGATION
To move among the tabbed folders, press the RIGHT or
LEFT key. The folder list is circular; that is, when the
SYSTEM folder is displayed and the LEFT key is pressed,
the SETTINGS folder becomes active. The same is true
when the SETTINGS folder is displayed and the RIGHT key
is pressed, the SYSTEM folder becomes active.
PAGE NAVIGATION
To move among the pages, press the UP and DOWN keys.
The page list is also circular. So, when page 1/4 (page 1 of
4) is active and the UP key is pressed, page 4/4 becomes
active. Also, when page 4/4 is active and the DOWN key is
pressed, page 1/4 becomes active. The current page for a
folder is persistent. For example, if you begin on the
SYSTEM folder page 2, change to the INFO folder and
return to the SYSTEM folder, page 2 will be the page
displayed.
3/3
SYSTEM
SETTINGS
INFO
Loaded
Remote
Load Selected
Power On Hours 12338
Running Hours 11445
Loaded Hours 11223
BCM Ver: 2.51
Number of Starts 35
1/3
SYSTEM
SETTINGS
INFO
Loaded
Remote
Load Selected
START
LOAD
UNLOAD
RESET
HORN SILENCE
CONTRAST
LEFT
UP
RIGHT
DOWN
ENTER
STOP
1/6
SYSTEM
SETTINGS
INFO
Loaded
Remote
Load Selected
Password * * * *
Setpoint Changes Enabled
English degF mils amps psi
Language and Units
Date, yyyy/mm/dd 1999/08/31
Time, hh:mm:ss 12:30:00
English degC mils amps kg/cm2
2/6
SYSTEM
SETTINGS
INFO
Loaded
Remote
Load Selected
MaxLoad (HLL) 400.0
User Setpoint (TL) 100.0
Surge Index Increment 1.0
Control Setpoint 100.0
Surge Absorber Enabled
Surge Sensitivity 9.0
MinLoad
6/6
SYSTEM
SETTINGS
INFO
Loaded
Remote
Load Selected
Alarm Trip
Stage 1 Temperature 120 125
Stage 1 Vibration 0.80 1.00
Stage 2 Temperature 120 125
Stage 2 Vibration 0.75 0.95
Oil Pressure 18 16
High Oil Temperature 120 125
Low Oil Temperature 100 95
4/6
SYSTEM
SETTINGS
INFO
Loaded
Remote
Load Selected
Modulate
Autodual
Reload Pressure, % of Setpoint 98
Unload Point, BV % Open 1
Unload Delay Time, seconds 1
Manual
Control Mode
5/6
SYSTEM
SETTINGS
INFO
Loaded
Remote
Load Selected
Starting Timer, seconds 20
CT Ratio 60
Motor Failure Trip Enable
Coasting Timer, seconds 240
Setpoint Ramp Rate, pressure/scan 5.0
Inlet Unload Position, % 15.0
3/6
SYSTEM
Loaded
Remote
Load Selected
PB IT D
Pressure 10.0 0.5 0.0
Pressure 10.0 0.5 0.0
MinLoad (TL) 25.0 0.5 0.0
MaxLoad (HLL) 100.0 0.5 0.0
SETTINGS
INFO
Inlet Valve
Bypass Valve
rep/sec sec
2/3
SYSTEM
SETTINGS
INFO
Not Ready
Remote
Trip
Event Name Time Date
1 Low Oil Pressure Trip 09:18:44 0720
2 Low Oil Pressure Alarm 09:18:43 0720
3 Reset key pressed 09:18:34 0720
4 Low Oil Pressure Trip 09:08:43 0720
5 Low Oil Pressure Alarm 08:58:23 0720
6 Load key pressed 08:24:01 0720
7 Start key pressed 08:23:12 0720
SYSTEM Folder
4/4
SETTINGS
INFO
SYSTEM
Digital Outputs
Loaded
Remote
Load Selected
Prelube Pump Running
CR1
Remote Trouble
3/4
SETTINGS
INFO
SYSTEM
Digital Inputs
Loaded
Remote
Load Selected
Starter Feedback
E-Stop Pressed
Low Seal Air
2/4
SETTINGS
INFO
SYSTEM
Press Temp Vib
Loaded
Remote
Load Selected
Stage 1 30.1 95.8 0.25
Stage 2 106.6 93.5 0.22
Oil 20.3 105.5
1/4
SETTINGS
INFO
SYSTEM
Motor
Current
System
Pressure
Pressure
Setpoint
105.1
105.0
323.4
Loaded
Inlet
Valve
Bypass
Valve
100
0
Remote
Load Selected
31-AUG-1999 12:00:00
Running Hours: 11445