![Ingersoll-Rand CENTAC Скачать руководство пользователя страница 150](http://html1.mh-extra.com/html/ingersoll-rand/centac/centac_technical-reference-manual_2059116150.webp)
140
CMC TECHNICAL REFERENCE MANUAL
1X36003 Version 2.52
1996-1999 Ingersoll-Rand Company
Date of Issue: 18-Oct-1999
Documentation
An Electrical Schematic drawing is provided as standard after order placement. Control Panel
Outline drawings are optional. Logic diagrams are considered proprietary and are not available.
System Information
Status Codes
The following table lists the status codes for the Base Control Module (BCM) only. These
codes indicate every operating condition, both normal and abnormal, for the system. A code
always exists for the system; for example, Status 05h indicates that the system is running
properly.
These codes, except Status 00h and 05h, are shown on a blank screen in the upper left
hand corner of the Operator User Interface (OUI). Since Status 00h and 05h are normal
operating conditions, these codes are not displayed. When a code is displayed, contact your
local Ingersoll-Rand Service Representative.
Status
Code
Definition
Comments
00h
Booting
The BCM is in the boot process. This is a normal process during BCM power up.
This state will not be displayed.
01h
Stay In Boot
The BCM is held in boot mode by the hardware configuration. This condition exists
only when the boot jumper (hardware device) is plugged into the display (OUI)
port. This hardware jumper is only required when doing system level
reprogramming of the module.
02h
ROM CRC Failed
The BCM software is not valid. This condition occurs when the CRC (Cyclic
Redundancy Check) calculated by the module does not equal the CRC value
written to the module when programmed. This would typically occur when the
programming process is aborted (halted). The module must be reprogrammed.
03h
Commanded To Boot
The BCM is currently in the process of being programmed. If this message does
not disappear after programming is completed, power cycle the unit.
04h
Invalid Application
The BCM software has failed to operate properly. Cycling the power on the module
will restart the system. Once restarted, the program will operate properly until the
same condition reoccurs.
05h
Application Running
Normal operating condition.
This state will not be displayed.
06h
Fatal Exit
Operating system error. Cycling the power on the module will restart the system.
Once restarted, the program will operate properly until the same condition
reoccurs.
07h
System Error
Operating system error. Cycling the power on the module will restart the system.
Once restarted, the program will operate properly until the same condition
reoccurs.
08h
Incompatible Software
Versions
The BCM application software and tables are not compatible. The module must be
reprogrammed.
09h
A-D System Error
Analog input system error. A hardware malfunction has occurred.
0Ah
D-A System Error
Analog output system error. A hardware malfunction has occurred.
0Bh
Digital I/O System Error
Digital input and output system error. A hardware malfunction has occurred.
0Ch
Logic Engine System or
Loop Task Error
Ladder logic processing system or loop task error. The module must be
reprogrammed.
0Dh
Comparator System Error
Comparator system error. The module must be reprogrammed.
0Eh
Operator User Interface
Error
Operator User Interface system error. Cycling the power on the module will restart
the system. Once restarted, the program will operate properly until the same
condition reoccurs.
0Fh
Data Logging System Error
Data logging system error. Cycling the power on the module will restart the
system. Once restarted, the program will operate properly until the same condition