PRODUCT
INFO
8
Installation and Servicing
Section 2 - Product Information
ⓘ
IMPORTANT: The following performance data is only applicable to brand new products
2.2 HEAT PUMP
Table 1 Data - Heat Pump
2.1 ERP DATA
Applicable ErP energy efficiency labels are supplied with each of the products. A separate ErP product fiche document is provided
with the Logic Air Heat Pump. If a Logic Air Cylinder product is installed, refer to
Table 2
to
Table 4
within this document for the
cylinder product fiche.
Description
Unit
4kW Logic Air
5kW Logic Air
8kW Logic Air
10kW Logic Air
Physical Properties
Packaged Weight - Gross (Unpackaged Weight (Net))
kg
96 (86)
96 (86)
123 (110)
123 (110)
Height (Unpackaged)
mm
980 (798)
980 (798)
1190 (1008)
1190 (1008)
Width (Unpackaged)
mm
1175 (1095)
1175 (1095)
1175 (1095)
1175 (1095)
Depth (Unpackaged)
mm
600 (521)
600 (521)
600 (518)
600 (518)
Performance Data
Coefficient of Performance (A+7 at W35 / W55)
COP
5.34 / 3.00
5.15 / 3.04
5.19 / 3.05
4.88 / 2.98
Coefficient of Performance (A-7 at W35 / W55)
COP
3.21 / 2.01
3.13 / 2.13
3.19 / 2.14
3.12 / 2.14
Seasonal Coefficient of Performance (W35 / W55)
SCOP
4.96 / 3.48
5.07 / 3.65
5.16 / 3.70
5.19 / 3.73
Sound Power Level *
dB (A)
52
52
55
55
Sound Pressure Level @ 1m / 3m / 5m
dB (A)
44 / 34.5 / 30
44 / 34.5 / 30
47 / 37.5 / 33
47 / 37.5 / 33
Maximum Outdoor Temperature
°C
35
35
35
35
Minimum Outdoor Temperature
°C
-20
-20
-20
-20
Heat Output
A+7°C/W+35°C
kW
4.0
5.0
8.0
10
A+7°C/W+55°C
kW
4.0
5.0
8.0
10.0
A-7°C/W+35°C
kW
4.1
5.1
8.2
9.53
A-7°C/W+55°C
kW
3.7
4.8
7.5
8.5
Electrical Properties
Electrical Supply Requirements
Rated Supply Voltage
V
230
230
230
230
Frequency
Hz
50
50
50
50
No. of Supply Phases
-
Single
Single
Single
Single
Maximum Current
A
12
12
22
22
Fuse Rating
A
16
16
32
32
Outdoor Unit Properties
IP Rating
-
X4
X4
X4
X4
Compressor Control Type
-
Inverter
Inverter
Inverter
Inverter
Electrical Power Consumption
A+7°C/W+35°C
kW
0.75
0.97
1.54
2.05
A+7°C/W+55°C
kW
1.33
1.64
2.62
3.36
A-7°C/W+35°C
kW
1.28
1.63
2.56
3.05
A-7°C/W+55°C
kW
1.84
2.25
3.50
3.97
Heating Circuit Requirements
Hydronic Connections
“
1” BSP Male
1” BSP Male
1” BSP Male
1” BSP Male
Maximum Operating Pressure
bar
3
3
3
3
Minimum Flow Rate of the Hydronic Circuit
l/min
8.5
8.5
14.5
14.5
Maximum Flow Temperature
°C
60
60
60
60
Minimum Operating Water Temperature (without pre-heating)
°C
17
17
17
17
Minimum Primary System Volume
L
Refer to Primary Heating
System Requirements
Refer to Primary Heating
System Requirements
Refer to Primary
Heating System
Requirements
Refer to Primary
Heating System
Requirements
Hydraulic Resistance
-
Refer to Pump Curves Refer to Pump Curves
Refer to Pump
Curves
Refer to Pump
Curves
Refrigerant Data
Refrigerant
-
R32
R32
R32
R32
Factory Refrigerant Charge
grams
880
880
1,470
1,470
GWP Rating
-
675
675
675
675
ODL Rating
-
0
0
0
0
Flammability Rating
-
A2L
A2L
A2L
A2L
Maximum Circuit Pressure
bar
42
42
42
42
Compressor Type
-
Twin Rotary
Twin Rotary
Twin Rotary
Twin Rotary
Compressor Oil
-
RmM68
Alkylbenzene
RmM68
Alkylbenzene
RmM68
Alkylbenzene
RmM68
Alkylbenzene
* Tested in accordance with EN 12102-1 Annex A
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...