Section 2 - Product Information
PRODUCT
INFO
10
Installation and Servicing
2.3 DHW CYLINDERS
Table 2 Data - Single Zone Pre-plumbed Cylinders
Figure 4. Plan View - PP Single Zone - 475 mm
Figure 5. Plan View - PP Single Zone - 550 mm
Heat Up Time, HWA Heat Pump Test 002:2020 (flow rate 0.42l/s and flow temperature of 55°C)
Heat Up Time, BS EN 12897, G3 Performance Test (flow rate of 0.25l/s / 80°C).
The relative heat up times stated are based on the tests referenced above and carried out on all cylinders within the range. The stated test value may not reflect real life
performance within a residential environment.
1
2
3
4
5
6
7
8
Overh
eat T
herm
ostat
Con
trol T
herm
istor
CYLINDER
HOT OUTLET
ALLOW EXTRA 200MM
< - - - CLEARANCE FOR FILTER
& SPANNER ACCESS
CONTROL PANEL
MINIMUM
< - - CLEARANCE - - >
FOR REMOVAL
OF PTRV
<- MINIMUM WIDTH = 645 mm ->
<
- M
IN
IM
UM
D
EP
TH
=
6
25
m
m
->
236390 A01
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
Central Heating Return
28
4
Central Heating Flow
22
5
Tundish Outlet
22
6
Balanced Cold Feed
22/28
7
Mains Cold Supply
22/28
8
Hot Water Feed
22/28
1
2
3
4
5
6
7
8
Overh
eat T
herm
ostat
Con
trol T
herm
istor
CYLINDER
HOT OUTLET
CONTROL PANEL
MINIMUM
< - - CLEARANCE - - >
FOR REMOVAL
OF PTRV
ALLOW EXTRA 200MM
< - - - CLEARANCE FOR FILTER
& SPANNER ACCESS
<
- M
IN
IM
UM
D
EP
TH
=
7
00
m
m
->
<- MINIMUM WIDTH = 700 mm ->
236390 A01
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
Central Heating Return
28
4
Central Heating Flow
22
5
Tundish Outlet
22
6
Balanced Cold Feed
22/28
7
Mains Cold Supply
22/28
8
Hot Water Feed
22/28
Logic Air Single zone Pre-plumbed cylinders
General Description
150, 180; litre; 475mm & 550mm diameter; single coil cylinders intended for coupling with a range of heat pumps
5kW to 14kW; Pre-plumbed and pre-wired including control box. Intended for a single zone heating system
installation.
Assembly Model code/number
Logic Air DHW pre-
plumbed slimline cylinder
150L & control box 1-zone
Logic Air DHW pre-plumbed
slimline cylinder 180L &
control box 1-zone
Logic Air DHW pre-
plumbed cylinder 150L &
control box 1-zone
Logic Air DHW pre-plumbed
cylinder 180L & control box
1-zone
Assembly UIN
236203
236204
236198
236199
Cylinder model code/number
IDEPLUHP150PPSZSL
IDEPLUHP180PPSZSL
IDEPLUHP150PPSZ
IDEPLUHP180PPSZ
Energy Efficiency Class
B
C
B
B
Heat Loss
Watts
50
58
44
49
kWh/24h
1.21
1.40
1.07
1.18
Capacity (DHW content)
Litres
145
169
148
170
Volume heated by immersion heater
Litres
134
165
127
157
Weight Empty
kg
46
53
44
48
Weight Full
kg
192
222
192
219
Pressure Reducing valve setting
bar
3
3
3
3
Expansion relief valve setting
bar
4.5
4.5
4.5
4.5
Temperature setting of TPRV
°C
95
95
95
95
Pressure setting of TPRV
bar
6
6
6
6
Potable Expansion Vessel size.
Litres
18
18
18
18
Expansion Vessel charge
bar
3
3
3
3
Overall Width
mm
581
581
636
636
Overall Height
mm
1598
1870
1196
1384
Overall Depth
mm
606
606
683
683
Cylinder Diameter
mm
A
475
A
475
A
550
A
550
DHW outlet
mm
B
1579
B
1851
B
1177
B
1365
Cylinder Height
mm
C
1519
C
1791
C
1118
C
1306
TPRV port
mm
D
1292
D
1564
D
875
D
1063
Manual reset overheat thermostat pocket
mm
E
1051
E
1151
E
673
E
673
Primary flow
mm
F
544
F
544
F
544
F
544
Secondary return port
mm
G
-
G
-
G
-
G
-
Thermistor pocket
mm
H
668
H
759
H
532
H
584
Primary return
mm
J
95
J
95
J
95
J
95
Immersion heater pocket
mm
K
230
K
230
K
230
K
230
Cold water inlet
mm
L
1516
L
1788
L
1099
L
1287
Cylinder Drain
mm
M
220
M
220
M
220
M
220
CH1 Flow
mm
N
479
N
479
N
479
N
479
CH2 Flow (n/a to SZ version)
mm
P
-
P
-
P
-
P
-
CH Return
mm
Q
95
Q
95
Q
95
Q
95
Buffer Connections
mm
R
-
R
-
R
-
R
-
Buffer Inspection
mm
S
-
S
-
S
-
S
-
Buffer Drain
mm
T
-
T
-
T
-
T
-
Primary heat exchanger surface area
m
2
1.8
3.0
1.6
2.5
Primary heat exchanger capacity
Litres
6.4
10.6
5.6
8.5
HWA Heat pump Test
-
-
-
-
-
Primary heat exchanger thermal rating
kW
15.2
20.7
13.1
17.8
Heat up time from 10°C to 50°C
min
22.3
21.8
22.6
22.6
V40
Litres
158.9
205.0
139.8
186.0
BS EN 12897 Test
-
-
-
-
-
Primary heat exchanger thermal rating
kW
33.2
39.3
25.7
32.8
Primary heat exchanger pressure loss
bar
0.08
0.05
0.06
0.10
Heat up time from 10°C to 60°C
min
13.9
15.8
16.4
17.6
V40
Litres
215.7
291.0
198.2
270.0
Revision Level
D8.2
D8.2
D8.2
D8.2
applies to 236203 Logic Air DHW pre-plumbed slimline cylinder 150L & control
box 1-zone and 236204 Logic Air DHW pre-plumbed slimline cylinder 180L &
control box 1-zone
applies to 236198 Logic Air DHW pre-plumbed cylinder 150L & control box
1-zone and 236199 Logic Air DHW pre-plumbed cylinder 180L & control box
1-zone
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...