Section 2 - Product Information
PRODUCT
INFO
19
Installation and Servicing
2.5 CONTENTS PROVIDED WITH APPLIANCE
2.5.1 Monobloc Heat Pump
Refer to Section
4.1.3 on page 29
.
2.5.2 DHW Cylinders
Refer to
Table 7 for
components supplied with the DHW Cylinders
and Section
4.2.1 on page 34.
2.5.3 Control Box
Refer to Section
4.3.1 on page 38.
Brand reference code
IDEPLUHP
Nominal Volume
150 180 150 180 210 210 250 300 180 180 210 210 250 250 300 300
Pre-plumbed (PP)
PP
Single zone, Two Zone (SZ,TZ)
SZ
DZ
SZ DZ SZ DZ SZ DZ SZ DZ
Slimline-475mm/ Standard-550mm / Wide-630mm (SL/S/W)
SL
S
SL
S
W
No circulation pump, Low Loss Header / Buffer (NP/LLH/
BUFFER/MB)
NP NP NP NP LLH LLH LLH LLH
BUFFER
Pre-Plumbed unvented cylinder components
Inlet control group, inc. PRV, BCF, CV, ERV
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Temperature and pressure relief valve
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Tundish
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Cylinder drain valve, on cold inlet elbow, (22mm elbow with MT
cock)
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Correctly sized expansion vessel (supplied not fitted)
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Pre-wired controls
DHW thermistor
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
DHW cylinder overheat thermostat
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Pre-Plumbed Primary system components
HP flow and return temperature thermistor
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Full divert spring close 3 port valve, motor open for DHW
heating
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Low loss header, Inc. drain point
N
N
N
N
Y
Y
Y
Y
N
N
N
N
N
N
N
N
System by-pass valve
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
System filter fitted to the HP return, Inc. isolation valves
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Auto air valve on central heating returns
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Central heating zone pump, Inc. isolation valves
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
System filling loop
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Isolation valves on HP flow
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Isolation valves on CH returns
Y
Y
Y
Y
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
DHW Back up heat source
Immersion heater
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Expansion vessel ( supplied in a separate box)
Expansion vessel size
18
18
18
18
24
24
24
35
18
18
24
24
24
24
35
35
Table 7 Content provided with DHW Cylinders
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...