Section 5 - Commissioning
COMMISSIONING
48
Installation and Maintenance
ᘐ
WARNING: Prior to activating the control box, make
sure that all requirements and checks from sections
5.1
and 5.3
have been completed. Electrical circuits require
verification of safety to reduce risk of electric shock or
damage to the system.
ᘐ
WARNING: The Heat Pump must have the power
active for a minimum of 6 hours prior to activation of the
heating function to protect the compressor.
ⓘ
IMPORTANT: To use the control screen the dial can
be rotated clockwise to move selection downwards, anti-
clockwise to move selection upwards, and pressed to
select. When options are selected, the dial can be turned
to cycle through the setting options. To exit menus or
return to previous screens, a selectable option will be
displayed at the bottom of the screen.
When the control box is first activated, the screen shown
below will display. The ‘1 Time’ and ‘2 Date’ can be set on this
screen. When set, select ‘Continue’ to move onto the next
screen.
ⓘ
IMPORTANT: The date and time must be set correctly so
that a heating schedule can be set up. Some setup functions
may not be possible to trial run if this is not set correctly.
14:42
06.05.2022
Continue
Quick Set Up (Step 1 of 3)
1 Time
2 Date
1
14:42
The following screen will be shown:_
Set the power rating to 4, 5, 8 or 10 kW as applicable. The
power rating displayed on the data plate of the Heat Pump is
then in putted into ‘5703 Heat Pump Power Rating’.
‘5700 Heating Circuits No & Type’ must then be set to the type
of system from the options below:
-
1 Underfloor Circuit.
-
1 Radiator Circuit.
-
2 Radiator Circuits.
-
1 Radiator and 1 Underfloor Circuit.
-
2 Underfloor Circuits.
-
Heat Pump Slave.
When set, select ‘Continue’ to move onto the next screen.
10 kw
2 Radiator Circuits
Continue
Quick Set Up (Step 2 of 3)
5703 Outdoor Unit Power Rating
5700 Heating Circuits N
o
& Type
Back
1
14:42
The following screen will be shown. ‘5895 Backup heater’ is
to be set to the appropriate option from the following:
-
None.
-
Immersion Heater.
- Boiler.
Legionella Protection is enabled as default and should only
be disabled with a heat only system configuration i.e. no DHW
cylinder.
When set, select ‘Continue’ to move onto the next screen.
Immersion heater
Enabled (1 h/week)
Continue
Quick Set Up (Step 3 of 3)
5895 Backup heater
1640 Legionella Protect
Back
1
14:42
A final screen is then shown to confirm that the settings have
been correctly set. Once confirmed, select ‘Continue’ to
complete quick set up and move onto the home screen.
Continue
Quick Set Up Complete
Back
1
14:42
Select continue again once the system has configured then
the home screen will be shown.
40.0ºC
31.8ºC
3.1ºC
12l/min
100%
Off
Off
DHW
Off
Primary flow temp
Hot water temp
Outside temp
Primary water flow
Compressor
CH1 Pump
CH2 Pump
Diverter valve
Immersion heater
1
14:42
5.5 ACTIVATION OF SYSTEM - QUICK SETUP
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...