Section 5 - Commissioning
COMMISSIONING
54
Installation and Maintenance
Press the dial and then rotate the dial until the following screen
is shown:
Back
On
55ºC
Set time program
Operating mode
DHW temp setpoint
Time program
Domestic hot water
08:32
Press the dial and then rotate the dial until the following screen
is shown:
Back
On
55ºC
Set time program
Operating mode
DHW temp setpoint
Time program
Domestic hot water
08:32
Press the dial so that the following screen is shown:
Zone 1
Heating
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Back
08:32
Press the dial so that the following screen is shown:
Back
Monday
Set time program
00:00 to 06:00
Copy
08:32
Rotate the dial until the time period you wish to change is
highlighted then press the dial and then rotate the dial to change
and finally press the dial when finished.
CHANGING ACCESS LEVEL FROM END USER TO
INSTALLER
20.0ºC
20.0ºC
3.1ºC
0l/min
0%
Off
Off
CH
Off
Primary flow
Hot water temp
Outside temp
Primary water flow
Compressor
CH1 Pump
CH2 Pump
Diverter valve
Immersion heater
08:32
Starting from the Home Screen (see above), to change the
Access Level from End User to Installer, rotate the dial until the
settings icon in the left-hand column is highlighted and press the
dial. The following screen will be shown:-
Set Time/Date
Special operations
User settings
User information
Installer
08:32
Rotate the dial until Installer is highlighted and then press the
dial and the following screen will be shown:-
Back
Enduser
Expert
Select user level
Enter password
08:32
Press the dial and rotate the dial until Installer is shown then
press the dial. Rotate the dial until the password line is
highlighted and press the dial then rotate and press the dial in
turn setting to 12345.
ⓘ
Installer Access will timeout after 15 minutes, if the
screen is left idle and will result in reverting back to End
User Access.
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...