Section 6 - Inspection and Maintenance
INSP
& MAINT
66
Installation and Maintenance
6.2.5 Fault History
6.2.6 Update the Settings
To use the control screen the dial can be rotated clockwise to
move selection downwards, anti-clockwise to move selection
upwards, and pressed to select. When options are selected,
the dial can be turned to cycle through the setting options. To
exit menus or return to previous screens, a selectable option
will be displayed at the bottom of the screen.
The fault codes on the control box are to be reviewed through
the following method:
1. Select the settings option.
2. Changing the user level to installer.
3. Enter the password.
4. If successful, this will then show the test function menu .
5. Select the test function menu and then select ‘Fault
History’.
6. In this menu, the previous 10 faults can be scrolled through
by selecting ‘Fault History (1/10)’ and scrolling.
Faults are to be reviewed for unexpected errors.
Installer
_ _ _ _ _ _
Back
Expert
Select user level
Enter password
08:32
Relay Test
Simulate Out’ Temp’
Heat Pump Status
Outside Temp’
Fault History
Versions
08:32
( 1/10 )
Back
Fault History
6800 History 1
15:15
6801 Fault Code 1
370:Thermodynamic source
08:32
The end user is to be surveyed on their heating performance
comfort levels. Any issues are to be addressed and settings to
be updated accordingly to improve the end users. For setting
instructions see Section
5.7.
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...