Section 2 - Product Information
PRODUCT
INFO
14
Installation and Servicing
Table 4 Data - Single Zone Pre-plumbed Cylinder with Integrated Buffer
Heat Up Time, HWA Heat Pump Test 002:2020 (flow rate 0.42l/s and flow temperature of 55°C)
Heat Up Time, BS EN 12897, G3 Performance Test (flow rate of 0.25l/s / 80°C).
The relative heat up times stated are based on the tests referenced above and carried out on all cylinders within the range. The stated test value may not reflect real life
performance within a residential environment
Figure 12.
Plan View - PP Single Zone Buff - 550 mm
Figure 13.
Plan View - PP Single Zone Buff - 630 mm
1
2
3
6
7
8
9
10
Over
heat
Ther
mos
tat
Co
ntr
ol T
her
mis
tor
CYLINDER HOT OUTLET
4
5
CONTROL PANEL
MINIMUM
< - CLEARANCE - >
FOR REMOVAL
OF PTRV
ALLOW EXTRA 200MM
< - - - CLEARANCE FOR FILTER
& SPANNER ACCESS
236399
<- MINIMUM WIDTH = 705 mm ->
<
- M
IN
IM
UM
D
EP
TH
=
7
10
m
m
->
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
Dual Zone Version
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
Central Heating Return
22/28
4
Central Heating Return
22/28
5
Central Heating Flow Z1
22/28
6
Central Heating Flow Z2
22/28
7
Tundish Outlet
22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
Single Zone Version
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
N/A
N/A
4
Central Heating Return
22/28
5
Central Heating Flow
22/28
6
N/A
N/A
7
Tundish Outlet
22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
1
2
3
6
7
8
9
10
Over
heat
The
rmo
stat
Co
ntr
ol T
her
mis
tor
CYLINDER HOT OUTLET
4
5
CONTROL PANEL
MINIMUM
< - CLEARANCE - >
FOR REMOVAL
OF PTRV
ALLOW EXTRA 200MM
< - - - CLEARANCE FOR FILTER
& SPANNER ACCESS
236399
<- MINIMUM WIDTH = 765 mm ->
<
- M
IN
IM
UM
D
EP
TH
=
7
90
m
m
->
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
Dual Zone Version
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
Central Heating Return
22/28
4
Central Heating Return
22/28
5
Central Heating Flow Z1
22/28
6
Central Heating Flow Z2
22/28
7
Tundish Outlet
22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
Single Zone Version
Number
Description
Size (mm)
1
Heat Pump Flow
28
2
Heat Pump Return
28
3
N/A
N/A
4
Central Heating Return
22/28
5
Central Heating Flow
22/28
6
N/A
N/A
7
Tundish Outlet
22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
Single Zone Pre-plumbed Cylinder with Integrated Buffer
General Description
180, 210, 250 & 300 litre; 550mm & 630mm diameter; single coil cylinders intended for coupling with a range of heat
pumps 5kW to 14kW; Pre-plumbed and pre-wired including control box. Intended for a single zone heating system
installation. These products incorporate a buffer which increases system volume and decouples the heat pump from the
central heating zone. It is possible to upgrade this product to a dual zone at a later date.
Assembly Model code/number
Logic Air DHW pre-plumbed
cylinder 180L, control box &
buffer 1-zone
Logic Air DHW pre-plumbed
cylinder 210L, control box &
buffer 1-zone
Logic Air DHW pre-plumbed
cylinder 250L, control box &
buffer 1-zone
Logic Air DHW pre-plumbed
cylinder 300L, control box &
buffer 1-zone
Assembly UIN
236206
236208
236210
236212
Cylinder model code/number
IDEPLUHP180DUOPPSZ
IDEPLUHP210DUOPPSZ
IDEPLUHP250DUOPPSZ
IDEPLUHP300DUOPPSZ
Energy Efficiency Class
B
B
B
B
Heat Loss
Watts
49
55
62
68
kWh/24h
1.18
1.33
1.49
1.63
Capacity (DHW content)
Litres
171
199
239
287
Volume heated by immersion heater
Litres
158
189
218
267
Weight Empty
kg
64.6
68.6
77
87
Weight Full
kg
305.6
337.4
379
437.5
Pressure Reducing valve setting
bar
3
3
3
3
Expansion relief valve setting
bar
4.5
4.5
4.5
4.5
Temperature setting of TPRV
°C
95
95
95
95
Pressure setting of TPRV
bar
6
6
6
6
Potable Expansion Vessel size.
Litres
18
24
24
35
Expansion Vessel charge
bar
3
3
3
3
Overall Width
mm
644
644
705
705
Overall Height
mm
1907
2095
1908
2128
Overall Depth
mm
702
702
780
780
Cylinder Diameter
mm
A
550
A
550
A
630
A
630
DHW outlet
mm
B
1888
B
2076
B
1889
B
2109
Cylinder Height
mm
C
1829
C
2017
C
1829
C
2049
TPRV port
mm
D
1586
D
1774
D
1572
D
1792
Manual reset overheat thermostat pocket
mm
E
1151
E
1151
E
1151
E
1151
Primary flow
mm
F
742
F
742
F
742
F
742
Secondary return port
mm
G
-
G
1664
G
1491
G
1678
Thermistor pocket
mm
H
1109
H
1172
H
1101
H
1174
Primary return
mm
J
117
J
117
J
82
J
82
Immersion heater pocket
mm
K
744
K
744
K
736
K
736
Cold Water Inlet
mm
L
1810
L
2000
L
1796
L
2016
Cylinder Drain
mm
M
744
M
744
M
736
M
736
CH1 Flow
mm
N
118
N
118
N
83
N
83
CH2 Flow (n/a to SZ version)
mm
P
118
P
118
P
83
P
83
CH Return
mm
Q
118
Q
118
Q
83
Q
83
Buffer Connections
mm
R
375
R
375
R
340
R
340
Buffer Inspection
mm
S
360
S
360
S
325
S
325
Buffer Drain
mm
T
221
T
221
T
219
T
219
Primary heat exchanger surface area
m
2
2.5
2.5
2.5
3.0
Primary heat exchanger capacity
Litres
8.5
10.6
8.5
10.6
Buffer Capacity
Litres
70
70
63.5
63.5
HWA Heat pump Test
-
-
-
-
-
Primary heat exchanger thermal rating
kW
17.8
14.5
23.6
14.3
Heat up time from 10°C to 50°C
min
22.2
32.7
26.6
44.1
V40
Litres
185.5
224.3
260.2
295.8
BS EN 12897 Test
-
-
-
-
-
Primary heat exchanger thermal rating
kW
35.1
37.2
37
39.2
Primary heat exchanger pressure loss
bar
0.08
0.05
0.05
0.04
Heat up time from 10°C to 60°C
min
14.5
16.4
20.3
21.8
V40
Litres
241.5
288.4
354.5
402.2
Revision Level
D8.2
D8.2
D8.2
D8.2
applies to Logic Air DHW pre-plumbed cylinder 180L, control box & buffer 1-zone and
Logic Air DHW pre-plumbed cylinder 210L, control box & buffer 1-zone
applies to Logic Air DHW pre-plumbed cylinder 250L, control box & buffer 1-zone and
Logic Air DHW pre-plumbed cylinder 300L, control box & buffer 1-zone
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...