Section 2 - Product Information
PRODUCT
INFO
18
Installation and Servicing
Table 6 Data - Control Box
2.4 CONTROL BOX
Physical Properties
Packaged Weight - Gross (unpackaged Weight)
kg
8.5 (5)
Height (unpackaged)
mm
796 (627)
Width (unpackaged)
mm
320 (254)
Depth (unpackaged)
mm
176 (147)
Maximum Ambient Temp
° C
60
Electrical Properties
IP Rating.
IP
20
Rated Voltage.
VAC
220-240
Maximum Rated Current (Control Box)
A
1
Maximum Rated Current (Contactor)
A
16
Rated Power Input (Control Box)
W
100
Rated Power Input (Contactor)
W
3000
Frequency
Hz
50
2.4.1 Control Box Dimensions and Clearances
ᘐ
CAUTION: Do not obstruct the product by any
surrounding objects or surfaces as this can limit
access and adversely affect performance. The minimum
clearances that are shown in
Figure 21
should be always
maintained.
ⓘ
IMPORTANT: Front clearance can be reduced to 5mm
(e.g. cupboard installation) but must maintain 900 mm
serviceable access.
Figure 20. Control Box - Dimensions
Figure 21. Control Box - Clearances
139
603
24
8
237
17
29
533
18
201
200 mm
200 mm
20 mm
200 mm
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...