Section 5 - Commissioning
COMMISSIONING
51
Installation and Maintenance
To change the setpoint, select the setpoint function and
change the value to 65°C
Return to the home screen by selecting the back arrow and
then the home symbol.
The display will change to the following:
20.0ºC
20.0ºC
3.1ºC
10l/min
100%
Off
Off
DHW
Off
Primary flow temp
Hot water temp
Outside temp
Primary water flow
Compressor
CH1 Pump
CH2 Pump
Diverter valve
Immersion heater
08:32
If you are installing a Halo Air alongside the Logic Air.
Proceed to section 5.7.3. (Section 5.7.2 is for reference
only).
5.7.2 Menu Operation
SETTING THE CENTRAL HEATING TIME PROGRAM
On/Off non-programmable room stats only
20.0ºC
20.0ºC
3.1ºC
0l/min
0%
Off
Off
CH
Off
Primary flow temp
Hot water temp
Outside temp
Primary water flow
Compressor
CH1 Pump
CH2 Pump
Diverter valve
Immersion heater
08:32
Starting from the Home Screen (see above), to set a central
heating programme, rotate the dial until the thermometer icon
in the left-hand column is highlighted and press the dial. The
following screen will be shown:-
Heating zone 1
40.0ºC
40.0ºC
--ºC
Heating
Primary flow temp
Flow temp setpoint
Room temperature
Time program
08:32
Press the dial and then rotate the dial until the desired central
heating zone is shown then press the dial again, rotate the dial
until the Time program is highlighted and then press the dial
again. The following screen will be shown:-
Zone 1
Heating
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Back
08:32
Rotate the dial until the desire day for setting is shown and
then press the dial.
The following screen will be shown:
Back
Zone 1
Monday
Set time program
06:00 to 08:00
Copy
08:32
Move the highlighted area to the time you wish to change using
the dial and press the dial, then rotate the dial to change the
time and press the dial to save.
SCAN
for Halo Air
Installation
Guide
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...