Section 2 - Product Information
PRODUCT
INFO
20
Installation and Servicing
2.6 LOCATION OF DATA PLATES
2.6.1 Heat Pump
The data plate can be found on the side of the Heat
Pump as shown in
Figure 22
.
2.6.2 DHW Cylinder
The location of the main data plate and warning label,
shown in
Figure 23,
can be different depending upon the
model of the DHW Cylinder.
2.6.3 Control Box
The main data plate can be found on the inside of the control
box door as shown in
Figure 24
.
The tear off strips of the data plate can be found on the side
of the control box,
Figure 24
and on the front of the literature
pack envelope.
002800600000001
Logic Air 8kW
Logic Air 8kW
Code 750666
Compressor / Compresseur
1 ~ 50Hz - 230V
3
MAXIMUM LOW PRESSURE REFRIGERATION CIRCUIT
BASSE PRESSION MAXI CIRCUIT FRIGORIGENE
HEAT TRANSFER FLUID
FLUIDE CALOPORTEUR
MAX. OPERATING PRESSURE COOLANT FLUID
PRESSION MAXI CIRCUIT CALOPORTEUR
INGRESS PROTECTION
INDICE DE PROTECTION
Code 750666
OUTDOOR TEMPERATURE LIMITS FOR HEATING / DHW OPERATION
LIMITE DE FONCTIONNEMENT CHAUFFAGE / ECS
PED Manufacturing site :GROUPE ATLANTIC/SIC Rue des Fondeurs BP64 59660 MERVILLE France :
IDEAL BOILERS PO box 103, NATIONAL AVENUE , KINGSTON UPON HULL HU5 4JN
2
1
22A
1 Supply voltage
Tension d'alimentation
R32 / 1470g / GWP 675
4.2 MPa (42 bar)
0.3 MPa (3 bar)
Water
Eau
IPX4
-20/+35°C
Serial Number
2
3
Maximum current
Intensité max
Power absorbed
Puissance absorbée
00U07302210-A
1.58kW
02/2023
Date
02/2023
4
Heat output (+7°C/+35°C)
Puissance calorifique
4
8.2kW
weight / poids :
110 kg
012-C700133
002
800600
000001
REFRIGERANT GROUP 1 (TYPE / CHARGE / GWP)
FLUIDE FRIGORIGENE GROUPE 1 (TYPE/CHARGE/GWP)
HERMETICALLY SEALED
CONTAINS FLUORINATED GREENHOUSE GASES / CONTIENT DES GAZ A EFFET DE SERRE FLUORES
0035
MAXIMUM HIGH PRESSURE REFRIGERATION CIRCUIT
HAUTE PRESSION MAXI CIRCUIT FRIGORIGENE (PS)
2.76 MPa (27.6 bar)
MAXIMUM TEMPRATURE REFRIGERANT
TEMPERATURE MAXIMALE FLUIDE FRIGORIGENE
130°C
MINIMUM TEMPERATURE REFRIGERANT
TEMPERATURE MINIMALE FLUIDE FRIGORIGENE
-40°C
075066600000001
075066600000001
KIWA 00027/021 HP
Inside view of
control box door
Side View of
control box
Side View of
Heat Pump
Figure 22. Heat Pump - Location of Data Plates
Figure 23. DHW Cylinder - Location of Data Plates
Figure 24. Control Box - Location of Data Plates
Содержание Logic Air DHW IDEPLUHP180DUOPPSZ
Страница 80: ...80 Installation and Maintenance Appendix 1 1 SYSTEM SCHEMATICS 1 1 1 Schematics Key Legend...
Страница 81: ...Appendix 81 Installation and Maintenance 1 1 2 Logic Air Two Zone Pre Plumbed Cylinder with Integrated Buffer...
Страница 82: ...Appendix 82 Installation and Maintenance 1 1 3 Logic Air Single Zone Pre Plumbed Cylinder...
Страница 92: ...92 Installation and Maintenance Notes...
Страница 93: ...93 Installation and Maintenance Notes...