4. Parameter Code List
37
Code
Function name
Setting range
Initial
data
Change
mode
on run
Page
I047
Software lock mode selection
0 (All parameters except I047 are locked when
SFT is on),
1 (All parameters except I047, F001 are locked
when SFT is on),
2 (All parameters except I047, F001 and User
group are locked when SFT is on),
3 (All parameters except I047 are locked),
4 (All parameters except I047, F001 are locked),
5 (All parameters except I047, F001 and User
group are locked)
1
○
96
I048 Up/Down
Selection
0(Data conservation radish),
1(Data conservation existence)
0
○
101
I049
AT terminal selection
0(O/OI), 1(O/O2)
0
ⅹ
97
I050
Reset selection
0(TRIP (On)), 1(TRIP (Off)), 2(ONLYTRIP (On))
0
○
99
I051
Reset frequency matching selection
0(Zero HZ), 1(Frequency matching)
0
○
99
Table 4- 7 Intelligent input terminal setting (I-group)
4.2.8
Intelligent output terminal setting (o-group)
Code
Function name
Setting range
Initial
data
Change
mode
on run
Page
o001
Intelligent output 1 setting
1
○
109
o002
Intelligent output 2 setting
0
○
109
o003
Intelligent output 3 setting
3
○
109
o004
Intelligent output 4 setting
Intelligent output setting reference
7
○
109
o005
Intelligent output 1 selection
0
○
110
o006
Intelligent output 2 selection
0
○
110
o007
Intelligent output 3 selection
0
○
110
o008
Intelligent output 4 selection
Intelligent output contact setting
(0 : N.O., 1 : N.C.)
0
○
110
o009
FM output selection
0(FREQ_OUT), 1(CURR_OUT),
2(TORQ_OUT), 3(DFREQ_OUT),
4(VOL_OUT), 5(POW_IN),
6(LOAD RATE), 7(FREQ_LAD)
0
○
120
o010 FM
offset
-3.00~10.00
-3.00
○
121
o011 FM
adjustment
0.0~255.0
80.0
○
121
o012
AM output selection
0(FREQ_OUT), 1(CURR_OUT),
2(TORQ_OUT), 3(VOL_OUT),
4(POW_IN), 5(LOAD RATE),
6(FREQ_LAD)
0
○
122
o013 AM
offset
0.00~10.00
0.96
○
122
o014 AM
adjustment
0.0~255.0
100.0
○
122
o015
AMI output selection
0(FREQ_OUT), 1(CURR_OUT),
2(TORQ_OUT), 3(VOL_OUT),
4(POW_IN), 5(LOAD RATE),
6(FREQ_LAD)
0
○
122
o016 AMI
offset
0.00~20.00
4.00
○
122
o017 AMI
adjustment
0.0~255.0
100.0
○
122
o018
Frequency arrival setting for
acceleration
0~99.99/100.0~400.0[Hz] 0.00
○
114
o019
Frequency arrival setting for
deceleration
0~99.99/100.0~400.0[Hz] 0.00
○
114
o020
Frequency arrival setting for
acceleration 2
0~99.99/100.0~400.0[Hz] 0.00
○
114
o021
Frequency arrival setting for
deceleration 2
0~99.99/100.0~400.0[Hz] 0.00
○
114
o022
Over-torque level 1
0~200[%]
100
○
117
o023
Over-torque level 2
0~200[%]
100
○
117