N700 Operating Instructions and Parts Manual
4. Parameter Code List
29
4.2.3 Fundamental
functions(F-group)
Code
Function name
Setting range
Initial
Data
Change
mode
on run
Page
F001
Output frequency setting
0.00~99.99/100.0~400.0[Hz]
0.00
○
46
F201
Output frequency setting,
2nd motor
0.00~99.99/100.0~400.0[Hz] 0.00
○
46
F002
Base frequency setting
30.00~99.99/100.0~400.0, up to max. frequency[Hz] 60.00
ⅹ
46
F202
Base frequency, 2nd motor
30.00~99.99/100.0~400.0, up to max. frequency[Hz] 60.00
ⅹ
46
F003
Maximum frequency setting
30.00~99.99/100.0~400.0, from base frequency[Hz] 60.00
ⅹ
47
F203
Maximum frequency setting,
2nd motor
30.00~99.99/100.0~400.0, from base frequency[Hz] 60.00
ⅹ
47
F004
Starting frequency setting
0.10~10.0[Hz]
0.50
○
48
F005
Frequency upper limit
0.00~99.99/100.0~400.0[Hz]
Frequency min. ~ Max. frequency
0.00
○
48
F205
Frequency upper limit, 2nd
motor
0.00~99.99/100.0~400.0[Hz]
Frequency min. ~ Max. frequency
0.00
○
48
F006 Frequency
lower
limit
0.00~99.99/100.0~400.0[Hz]
Starting frequency ~ Max. frequency
0.00
○
48
F206
Frequency lower limit, 2nd
motor
0.00~99.99/100.0~400.0[Hz]
Starting frequency ~ Max. frequency
0.00
○
48
F007
Accelerating time setting
0.1~999.9,1000.~3600.[sec]
30.0
○
49
F207
Accelerating time setting,
2nd motor
0.1~999.9,1000.~3600.[sec] 30.0
○
49
F008
Decelerating time setting
0.1~999.9,1000.~3600.[sec]
30.0
○
49
F208
Decelerating time setting,
2nd motor
0.1~999.9,1000.~3600.[sec] 30.0
○
49
F009
Driving direction selection
0(FWD), 1(REV)
0
ⅹ
50
F010
Frequency source selection
0(OPE VOL), 1(TERMINAL), 2(OPE KEYPAD),
3(COM), 4(OPT1), 5(OPT2)
0
ⅹ
50
F011
RUN command source
selection
1(TERMINAL), 2(OPE), 3(COM), 4(OPT1), 5(OPT2)
2
ⅹ
51
F012
Motor control method
0(VC), 1(VP1), 2(VP2), 3(FREE V/f), 4(SLV-I),
5(SLV-D), 6(V2), 7(0Hz-V2)
0
ⅹ
52
F212
Second motor control method
0(VC), 1(VP1), 2(VP2), 3(FREE V/f), 4(SLV-I), 5(SLV-D)
0
ⅹ
52
F013
Motor voltage selection
(Motor rated voltage)
200/215/220/230/240[V]
380/400/415/440/460/480[V]
220
(440)
ⅹ
53
F014
Output voltage gain
20~100[%]
100
○
54
F015
Motor capacity selection
(Motor rated capacity)
1.5/2.2/3.7/5.5/7.5/11/15/18.5/22/30/37/45/55/75
/90/110/132/160[
㎾
]
Factory
setting
ⅹ
54
F215
2nd Motor capacity selection
(Second motor rated capacity)
1.5/2.2/3.7/5.5/7.5/11/15/18.5/22/30/37/45/55/75
/90/110/132/160[
㎾
]
Factory
setting
ⅹ
54
F016
Motor pole selection
2/4/6/8/10/12[Pole]
4
ⅹ
54
F216
Second motor pole selection
2/4/6/8/10/12[Pole]
4
ⅹ
54
F017
Motor rated current setting
0.0~999.9[A]
Factory
setting
ⅹ
55
F217
Second motor rated current
0.0~999.9[A]
Factory
setting
ⅹ
55
F018 Speed/Torque mode selection
0(Speed control mode)/1(Torque control mode)
0
ⅹ
55
F019
SLV control method selection
0(Normal operation mode), 1(0Hz operation mode)
0
ⅹ
55
Table 4- 3 Fundamental functions(F-group)