N700 Operating Instructions and Parts Manual
5. Explanation of d-Group Function
42
5. E
XPLANATION OF D
-
GROUP
5.1
Output frequency monitor (d001)
(1) Indication code d001 displays output frequency to motor.
(2) The data is displayed as follows.
When d001 is displayed, the monitor lamp "Hz" is illuminated.
①
0.00 ~ 99.99 : Display is in 0.01Hz unit.
②
100.0 ~ 400.00 : Display is in 0.1Hz unit.
(3) It is displayed to value that is set in output frequency setting (F001) in running condition.
(4) In case that frequency setting method (F010) is operator keypad setting parameter(2), output
frequency is adjustable in this code d001.
5.2
Motor rotation direction monitor (d002)
(1) Indication code d002 displays the direction that the Inverter output is rotating.
Forward, reverse or stop.
①
Forward : F
②
Reverse : r
③
Stop : o
(2) On operating the inverter (in case of CW(FWD) or CCW(REV)), the RUN lamp will illuminate.
5.3
Output current monitor (d003)
(1) Indication code d003 displays the output current value.
(2) The data is displayed as follows.
0.0 ~ 999.9 : Display is in 0.1 A unit.
In case of displaying d003, the monitor lamp "A" is illuminated.
(3) The output current is displayed in RMS value according to the load current.
5.4
Output voltage monitor (d004)
(1) This inverter displays the output voltage of the inverter converted into the alternating voltage.
0.0 ~ 999.9 : Display is in 0.1V unit.
(2) In case of displaying d004, the monitor lamp "V" is illuminated.
5.5
DC link voltage monitor (d005)
(1) Indication code d005 displays the DC link voltage of the inverter.
0.0 ~ 999.9 : Display is in 0.1V unit.
5.6
Motor input power monitor (d006)
(1) Display output electric power from inverter.
0.0 ~ 999.9 : Display is in 0.1
㎾
unit.
(2) In case of displaying d006, the monitor lamp "V" and "A" ("
㎾
" ) is illuminated.