N700 Operating Instructions and Parts Manual
9. Explanation of I-Group Function
86
code
Function
name
Code
value
Contents
Item
13
USP
Unattended start protection
Unattended start protection
function
15
SFT
Software lock(control terminal)
Software lock
16
AT
Analog input voltage/current select
Analog external input
17
RESET Reset inverter
Reset inverter
18 STA
3wire
start
19 STP
3wire
stop
20 F/R
3wire
direction(forward/reverse)
3wire input function
21
PID
PID selection (valid/invalid)
22
PIDC PID integrating reset
PID function
24
UP
Remote control UP function
25
DOWN Remote control DOWN function
26
UDC
Remote control data clear
Remote control UP/DOWN
function
27
OPE
Force operation start
Force operation starting function
29
TL
Torque restriction presence
30
TRQ1 Torque limit switching 1
31
TRQ2 Torque limit switching 2
Torque limit function
33 BOK
Brake
confirmation
Brake control function
34 ORT
Orientation
35 LAC
LAD
cancel
36
PCLR Position deviation clear
37
STAT Pulse train input permission
Option function (Refer to
feedback function)
38 XT1
Multi-step
acceleration/deceleration time 1
39 XT2
Multi-step
acceleration/deceleration time 2
40 XT3
Multi-step
acceleration/deceleration time 3
Multi-step
acceleration/deceleration Time
function
Table 9- 2 Input terminal function selection (I001~I008)
(4) The initial function setting(I001~I008) for the intelligent input terminal is like the following :
Code
Function name
Initial value
Unit
Set range
Contents
I001
Intelligent 1 Input
17
-
0~40
Initial value is setting by 17 (RESET)
I002
Intelligent 2 Input
16
-
0~40
Initial value is setting by 16(AT)
I003
Intelligent 3 Input
6
-
0~40
Initial value is setting by 6(JOG)
I004
Intelligent 4 Input
11
-
0~40
Initial value is setting by 11(FRS)
I005
Intelligent 5 Input
9
-
0~40
Initial value is setting by 9(2CH)
I006
Intelligent 6 Input
3
-
0~40
Initial value is setting by 3(CF2)
I007
Intelligent 7 Input
2
-
0~40
Initial value is setting by 2(CF1)
I008
Intelligent 8 Input
1
-
0~40
Initial value is setting by 1(REV)
Table 9- 3 The initial function setting(I001~I008) for the intelligent input terminal
Like the following example, each function needed to be set has to be assigned to I001~I008
code directly.
The initial setting value is as following: