Section IV.
Keyboard Operation
31
*RMP(Hz+A)revolving speed unit
*
%
(A+V)percentage
Digital display
Digital display area
*5-bit LED display,monitor set frequency,output frequency,various monitoring
data,alarm code etc.
PRG+>>/SHIFT=QUIC
K
Menu mode selection code,shift different menu mode according to the value
of PP.03 (Function parameter mode as default)
PRG
Programming key
*Primary menu enter or exit
>>/SHIFT
Shift key
*On the stop display interface or running display interface, it can be used to
circularly select the display parameters. When modifying the parameters, it
can be used to select the bits of parameter for modification
ENTER
Confirmation key
*Gradually step into the menu screen,set parameters confirmation
∧
Increasekey
*Increase of the data or function code
∨
Decreasekey
*Decrease of the data or function code
MF/REV
Multi-function selectionkey
*It is used as functions witching selection according to P7.01.
Potentiometer
Potentiometer
* P0.03 is set to 4 as default;
* Control board jumper J6 is in 1-2,keyboard potentiometer set frequency
* Control board jumper J6 is in 2-3, AI3 terminal set frequency
RUN
Runningkey
* It is used to start the running of the inverter under keyboard control mode
STOP/RESET
Stop/reset
* In running status,it can stop the running by pressing this key. In alarm
status,it can reset operation with this key. The characteristics of this key
are limited by function code P7.02.
Table 4-2.1