Timingcontrol
Timing control function
:
settimerange0Min~6500.0Min
Multiple motor switch
4 groups of motor parameter,which can realize 4-motor switch control
Multi-threaded bus support Support 3 kinds of field bus
:
RS485, Profibus-DP, CANopen
Motor overheat protection
Select optional H5PC1 analog input AI3x can accept the motor
temperature sensor input(PT100
、
PT1000)
Multi-encoder support
Support difference,open collector, UVW, rotary transformer, sine
cosine encoder etc.
Programmable PLC
Select optional user programmable card,which can realize secondary
development,programming mode compatible with Drino PLC.
Excellent backend software
Support inverter parameter operation and virtual oscilloscope
function.Inverter internal state graphic monitor can be realized
through virtual oscilloscope.
Running
Running command channel
Three types of channels
:
operation panel reference,control terminal
reference and serial communication port reference.These channel
scan be switched in various modes.
Frequency source
There are totally eleven types of frequency sources, such as digital
reference, analog voltage reference, analog current reference, pulse
reference, MS speed, PLC, PID and serial port reference.
Auxiliary frequency source
11 kinds of auxiliary frequency source which can flexible achieve
auxiliary frequency tuning, frequency synthesis
Input terminal
Standard
:
There are 6 digital input terminals,DI5 can be used as100kHz high-
speed input pulse.
2 analog input terminals which can be used as 0-10V voltage input or
0~20mA current input.
Extended function
:
4 digital input terminals,
1analog input terminals support-10~10V voltage input &PT100\PT100
Output terminal
Standard
:
1 digital output terminals, Y1 is high-speed pulse output terminal (can
be choosen as open circuit collector type), support 0~10kHz square
wave signal;
2 relay output terminal;
2 analog output terminals, support 0~20mA output current or 0~10V
output voltage;
Extended function
:
2 digital output terminal;;
1 analog output terminal, support 0~20mA output current or 0~10V
output voltage.
Keyboar
d oper
ation
LED display
Realizeparameter setting,statusmonitoringfunction
Keyboard potentiometer
Equipped with keyboard potentiometer or coding potentiometer
Key lock&function selection
Realize button locking,define operation range for part of buttons to
prevent operation fault.
Protection function
It can implement power-on motor short-circuit detection,input/output
phase loss protection, over current protection,over voltage
protection,under voltage protection,overheating protection and overload
protection.