Section V.
Parameter Function Table
Terminal
Set value
Description
DI1
1
Forward(FWD)
DI2
2
Reverse(REV)
Among them ,DI1
、
DI2 are DI1~DI10 muti-fuction input terminal, level valid.
0 invalid
,
1 valid
K1
K2
Command
0
0
Stop
0
1
Reverse(REV)
1
0
Forward(FWD)
1
1
Stop
Fig. 5-6 Two-line control mode 1
1
:
Two-line mode 2
:
In this operation mode,DI1 terminal function is to enable operation,while DI2 terminal function is to
determine running direction. The descriptions on the terminal running command are as shown as below
:
Terminal
Set value
Description
DI1
1
Forward(FWD)
DI2
2
Reverse(REV)
Among them
,
DI1
、
DI2 are DI1~DI10 multi-fuction input terminal, level valid
0 invalid
,
1 valid
K1
K2
Command
0
0
Stop
0
1
Stop
1
0
Forward(FWD)
1
1
Reverse(REV)
Fig. 5-7 Two-line control mode 2
2
:
Three-line mode1
K2
K1
DIx (FWD)
DIy (REV)
COM
HV590
K2
K1
DIx (FWD)
DIy (REV)
COM
HV590