14
Section II.
Installation &Wiring
2.1
Use of the environment
1) Ambient temperature-10
℃
~40
℃
.
2) Avoid electromagnetic interference and keep the unit away from the source of interference.
3) Prevent dropping water, steam, dust powder, cotton fiber or fine metal powderfrominvasion.
4) Prevent oil, salt and corrosive gas from entering it.
5) Avoid vibration. Vibration should be less than 0.6G. Keep away from punching machine etc.
6) Avoid high temperature, moisture or being wetted due to raining, with the humidity below
95%RH (non-condensing).
7) Prohibit the use in the dangerous environment where inflammable or combustible or explosive
gas, liquid or solid exists.
2.2
Handling and installation
※
When transporting inverter, right lifting tools are required to prevent inverter from
damaging.
※
The number of stacked box of the inverter are not permitted higher than the limit.
※
Please don’t run the inverter if there is damage or lacking of components.
※
Do not place heavy objects on the frequency inverter.
※
Please prevent screw, cable pieces or other conductive objects or oil etc
inflammableobjects invading the frequency inverter.
※
Do not make it fall or have a strong impact.
※
Confirm if the installation location and object could withstand the weight of the
inverter. The frequency inverter must be installed by wall hooking
、
inYor room
withadequate ventilation, with enough space left between it and the adjacent objects
or retaining board (walls) around, as shown in the picture below
:
Fig. 2-2.1
Air circulation position
Air circulation position
Above 120mm
Above 120mm
Air circulation position
Air circulation position
Above 120mm
Above 120mm