121
Section V.
Parameter Function Table
0.1s~10.0s
0.1s
A2.37
Tuning selection
No operation
0
0
★
Asynchronous static tuning
1
Asynchronous complete tuning
2
Synchronous static tuning
11
Synchronous complete tuning
12
A2.38 Speed loop proportional gain 1 1~100
30
☆
A2.39 Speed loop integration time1
0.01s~10.00s
0.50s
☆
A2.40 Switching frequency1
0.00~A2.43
5.00Hz
☆
A2.41 Speed loop proportional gain 2 0~100
20
☆
A2.42 Speed loop integration time 2
0.01s~10.00s
1.00s
☆
A2.43
Switching frequency 2
A2.40~maximum output frequency
10.00Hz
☆
A2.44
Vector control slip gain
50%~200%
150%
☆
A2.45
Speed-loop filtering time
0.000s~0.100s
0.000s
☆
A2.47
Torque upper limit source in
speed control mode
A2.48 setup
0
0
☆
AI1
1
AI2
2
AI3(Potentiometer)
3
PULSE setup
4
Communication setup
5
MIN(AI1,AI2)
6
MAX(AI1,AI2)
7
A2.48
Torque upper limit digital
setup in speed control
mode
0.0%~200.0%
150.0%
☆
A2.51
Excitation regulation
proportional gain
0~60000
2000
☆
A2.52
Excitation regulation
integration gain
0~60000
1300
☆
A2.53
Torque requlation
proportional gain
0~60000
2000
☆
A2.54
Torque regulation
integration gain
0~60000
1300
☆
A2.55
Speed loop integration
attribute
1bit
Integration separation
0
☆
Invalid
0
Valid
1