76
Section V.
Parameter Function Table
P5.17
Y1R output delay time
0.0s~3600.0s
0.0s
☆
P5.18
RELAY1 output delay time
0.0s~3600.0s
0.0s
☆
P5.19
RELAY2 output delay time
0.0s~3600.0s
0.0s
☆
P5.20
DO1 output delay time
0.0s~3600.0s
0.0s
☆
P5.21
DO2 output delay time
0.0s~3600.0s
0.0s
☆
Set output terminal Y1R, relay 1, relay 2, DO1 and DO2 delay time that begins from status changing to
real output changing.
P5.22
DO output terminal valid
state selection
1bit
Y1R valid state selection
00000
☆
Positive logic
0
Negative logic
1
10bit
RELAY1 terminal valid state setup
Positive logic
0
Negative logic
1
100bit RELAY2 terminal valid state setup
Positive logic
0
Negative logic
1
1000
bit
DO1 terminal valid state setup
Positive logic
0
Negative logic
1
10000
bit
DO2 terminal valid state setup
Positive logic
0
Negative logic
1
Define output terminal Y1R
、
Relay 1
、
Relay 2
、
DO1 andDO2 output logic.
0
:
Positive logic
Digital output terminals and the corresponding public end connected as effective state, disconnect for
invalid state.
1
:
Negative logic
Digital output terminals and the corresponding public end connected as invalid state, disconnect for
effective state.
5.8
Start/stop control
:
P6.00-P6.15
Code
Description/
Keyboard Display
Setting Range
Factory
Setting
Change
Limite
P6.00
Start mode
Direct startup
0
0
☆
Содержание HV590 Series
Страница 1: ...HV590 Series Frequency Inverter User Manual HNC Electric Limited ...