70
Section V.
Parameter Function Table
Curve2(2 points
,
see P4.18~P4.21)
2
Curve3(2 points
,
see P4.23~P4.26)
3
Curve4(4 points
,
see A6.00~A6.07)
4
Curve5(4 points
,
see A6.00~A6.07)
5
100bit AI3 curve selection
Curve1(2 points
,
see P4.13~P4.16)
1
Curve2(2 points
,
see P4.18~P4.21)
2
Curve3(2 points
,
see P4.23~P4.26)
3
Curve4(4 points
,
see A6.00~A6.07)
4
Curve5(4 points
,
see A6.00~A6.07)
5
The 1bit, 10bit, 100bit of the function code are used to choose the set curve of analog input AI1
、
AI2
、
AI3 respectively.
3 analog input can choose any curve of the 5 types.
Curve1, curve 2, curve 3 are 2 points curve that set through P4 group function codes, while curve 4,
curve 5 are 4 points curve that set through A8 group function codes.
HV590 standard unit offers 3-channel analog input terminals. Multi-function I/O expansion card is
needed in the use of AI3x.
P4.34
AI below minimum input
setup selection
1bit
AI1
below
minimum
input
setup
selection
000
☆
Minimum input setup
0
0.0%
1
10bit
AI2 below minimum input setup selection
Minimum input setup
0
0.0%
1
100bit AI3 below minimum input set selection
Minimum input setup
0
0.0%
1
This function code is used to dertermine analog quantity corresponding setup when analog input
voltage below the setup of minimum input.
The 1bit, 10bit, 100bit of the function code are corresponding to the analog input AI1
、
AI2
、
AI3
respectively. If the bit is set to 0 and AI is below the minimum setup , the analog input setup is the curve
“minimum input corresponding setup”(P4.14
、
P4.19
、
P4.24) . If the bit is set to 0 and AI is below the
minimum setup , the analog quantity corresponding setup is 0.0%.
P4.35
DI1 delay time
0.0s~3600.0s
0.0s
★
P4.36
DI2 delay time
0.0s~3600.0s
0.0s
★
P4.37
DI3 delay time
0.0s~3600.0s
0.0s
★
Only DI1, DI2, DI3 are able to set equipment delay time.
Содержание HV590 Series
Страница 1: ...HV590 Series Frequency Inverter User Manual HNC Electric Limited ...
Страница 189: ......