4 Planning and installation – Installing the heating system
71
17.
Set the position indicator (1) for the pressure equalisation regu-
lator to approximately "half open".
✓
The pressure equalisation hose is connected.
C
ONNECTING
THE
FEEDING
SYSTEM
18.
Insert the cable of the feeding system through the opening pro-
vided for it on the cladding.
19.
Connect the plug of the feeding system to the circuit board.
✎
See the enclosed circuit diagram “HDG Compatronic”.
✓
The feeding system is connected.
Figure 4/40 - Attaching the pressure equalisation hose
1
Содержание Compact 25