6 Using the heating system – Performing the chimney sweep test
109
T
EST
EVERY
TWO
YEARS
In Germany, regular inspections every two years must be carried out
in accordance with the requirements of the federal emission limits (1.
BImschV).
B
EFORE
THE
TEST
1.
Clean the heating system completely about 2-3 days prior to the
test.
✎
See the chapter entitled “7 Cleaning and servicing the heating
system”, section “7.1 Cleaning and maintenance schedule”.
2.
Check that the lambda sensor is securely mounted and tighten it
if necessary.
✎
See the chapter entitled “7 Cleaning and servicing the heating
system”, section “7.1 Cleaning and maintenance schedule”.
O
N
THE
DAY
OF
THE
TEST
Once the chimney sweep has completed the preparations for the
test:
1.
Press the
Mode
button repeatedly until the
Chimney sweep test
symbol flashes.
✓
The operating mode
Chimney sweep test
is preselected.
2.
Press the
Enter
button.
✓
The operating mode
Chimney sweep test
is confirmed.
✓
The
Chimney sweep test
symbol lights up.
✓
The heating system switches to
Chimney sweep test
mode.
✓
If the HDG Hydronic is connected, all of the loads will automati-
cally be activated to maximise the heat transfer.
✓
The display will show
No test yet
.
Caution!
Material damage and injury due to incorrect chimney sweep test
The chimney sweep test requires comprehensive technical know-
ledge.
Only permit authorised specialists to perform the chimney sweep
test.
Enter