6 Using the heating system – Structure of the menus
123
3-22
Ignition
Heating-up
Flue gas fan
( 20)
20%
•
Flue gas fan setting for heating-up phase
Setting option for the speed of a flue gas fan for the hea-
ting-up phase.
(0 - 100 %)
3-23
Ignition
Burn out
Duration
( 30)
30m
•
Burn-out time
The combustion fan runs for this amount of time while
the boiler burns out.
(1 - 30 min)
3-24
Ignition
Burn out
Primary air
( 45)
45%
•
Primary air for burning out
Setting option for the primary air volume supplied during
burning out.
(0 - 100 %)
3-25
Ignition
Burn out
Secondary air
( 45)
45%
•
Secondary air for burning out
Setting option for the secondary air volume supplied
during burning out.
(0 - 100 %)
3-26
Ignition
Burn out
Flue gas fan
( 60)
60%
•
Flue gas fan setting for burning out
Setting option for the speed of a flue gas fan for burning
out.
(0 - 100 %)
3-31
Ignition
Log wood
Primary air
( 20)
20%
•
Primary air for log wood emergency operation
Setting option for the primary air volume supplied during
log wood emergency operation.
(0 - 100 %)
3-32
Ignition
Log wood
Secondary air
( 40)
40%
•
Secondary air for log wood emergency operation
Setting option for the secondary air volume supplied
during log wood emergency operation.
(0 - 100 %)
3-33
Ignition
Log wood
Flue gas fan
( 20)
20%
•
Flue gas fan setting for log wood emergency opera-
tion
Setting option for the speed of a flue gas fan during log
wood emergency operation.
(0 - 100 %)
No.
Display
Description
Table 6/5 - System level / 3 - Ignition