6 Using the heating system – Structure of the menus
132
7-19
Delivery system
Delivery system
reverse current
( 3.0)
3.0A
•
Delivery system
After exceeding the set motor current, the motor reverses
up to three times. Then a fault message is issued. (0.1 -
10.0 A)
7-21
Delivery system
Delivery system
reverse runtime
( 1)
1s
•
Delivery system
Reverse running time when the set reverse current is
exceeded.
(0 - 3 s)
7-23
Delivery system
Fill level indicator
Switch-off delay
( 60)
60s
•
Delivery system
Set the switch-off delay of the fill level indicator in the pel-
let vacuum container or at the dosage transition.
7-24
Delivery system
Fill level indicator
Switch-on delay
( 3)
3s
•
Delivery system
Set the switch-on delay of the fill level indicator in the
dosage transition.
7-25
Delivery system
Delivery system
Maximum runtime
( 25)
25m
•
Delivery system
Set the maximum runtime of the vacuum fan in the pellet
vacuum container.
7-26
Delivery system
Enable times
On 00:00 On 00:00
Off 24:00 Off 00:00
•
Enable times
Time block: Enable times for the delivery system can be
defined.
7-27
Delivery system
Fill after
Dosage runtime
( 200)
200m
•
Delivery system
After the set time has elapsed, the pellet vacuum contai-
ner is re-filled.
7-28
Delivery system
Vacuum fan supply
( 10)
10s
•
Delivery system
Set the supply time of the vacuum fan up to the start of
the pellet auger.
7-29
Delivery system
Vacuum fan lag time
( 10)
10s
•
Delivery system
Set the vacuum fan lag time after the full signal of the pel-
let vacuum container.
No.
Display
Description
Table 6/9 - System level / 7 - Delivery system