7 Cleaning and servicing the heating system – Requirements
164
C
LEANING
THE
FLUE
GAS
TEMPERATURE
SENSOR
1.
Set the control to the operating mode
OFF
.
✓
The
OFF
symbol lights up.
2.
Allow the fire in the heating system to burn out and cool down.
3.
Turn the main switch off.
7.
Carefully mount the flue gas temperature sensor in the reverse se-
quence.
8.
Switch the heating system on again.
✎
See the chapter entitled “6 Using the heating system”, section
“6.2 Switching on the heating system”.
✓
The cleaning of the flue gas temperature sensor is completed.
C
HECKING
AND
LUBRICATING
THE
FILL
LEVEL
INDICATOR
1.
Set the control to the operating mode
OFF
.
✓
The
OFF
symbol lights up.
2.
Allow the fire in the heating system to burn out and cool down.
3.
Turn the main switch off.
4.
Open the front door.
Important!
✎
See “Generally applicable safety instructions” in this section.
4.
Release the flue gas tempera-
ture sensor (1) using a 13 mm
spanner.
5.
Pull the sensor (1) out of the
flue pipe (2).
6.
Clean the sensor (1) with a
moist cloth.
Figure 7/21 - Cleaning the flue gas temperature sensor
1
2
Important!
✎
See “Generally applicable safety instructions” in this section.