8 Troubleshooting – Possible faults
175
F141
Mains supply
line
Rotational
direction is
switched
•
Check mains supply line
•
Have the fault fixed by a qua-
lified electrician
F142
Mains supply
line
L2 is missing
•
Faulty mains fuse
•
Faulty mains supply line
•
Have the fault fixed by a qua-
lified electrician
F143
Mains supply
line
L3 is missing
•
Faulty mains fuse
•
Faulty mains supply line
•
Have the fault fixed by a qua-
lified electrician
F144
Mains supply
line L2 + L3
(K101 / K102)
•
Faulty mains fuse
•
Faulty mains supply line
•
Voltage not present at termi-
nals 101 and 102
•
Have the fault fixed by a qua-
lified electrician
F145
Feeding syst.
fault
K111-113
F10,F11,F13
•
Fuse is faulty
•
Motor is not connected
•
Have the fault fixed by a qua-
lified electrician
F146
Dosage fault
K108-110
F12,F15,F16
•
Fuse is faulty
•
Motor is not connected
•
Have the fault fixed by a qua-
lified electrician
F147
Delivery syst.
fault
K105-K107
F14,F17,F18
•
Fuse is faulty
•
Motor is not connected
•
Have the fault fixed by a qua-
lified electrician
F148
Transport module
(IO21) defective
•
Transport module is faulty
•
Have circuit board replaced
by a qualified electrician
F150
Safety circuit
Overfilling Lub-
ricating the
feeding
•
Check rotary feeder for com-
pacted material
•
Faulty limit switch
•
Cable not connected
•
Have the fault fixed by a qua-
lified heating engineer
F151
Safety circuit
Overfilling
Delivery system
•
Check dosing auger or deli-
very for overfilling
•
Faulty limit switch
•
Cable not connected
•
Have the fault fixed by a qua-
lified heating engineer
F152
Safety circuit
Fuel storage
door
•
Door switch is faulty
•
Cable not connected
•
Have the fault fixed by a qua-
lified heating engineer
•
Check plug on circuit board
122 /123
No.
Fault
Cause
Remedy
Table 8/1 - Faults