7 Cleaning and servicing the heating system – Requirements
159
3.
Turn the main switch off.
6.
Brush off the lambda sensor (2) with a brass brush.
7.
Clean out any deposits inside the connection nozzle (3).
8.
Reinstall the lambda sensor (2) in the reverse sequence.
9.
Check that the lambda sensor (2) for a secure fit.
10.
Carefully tighten the lambda sensor (2) with an SW22 spanner.
11.
Switch the heating system on again.
✎
See the chapter entitled “6 Using the heating system”, section
“6.2 Switching on the heating system”.
12.
Calibrate the lambda sensor.
✎
See chapter “5 Commissioning the system”, section
“5.2 Procedure”, paragraph “Calibrating the lambda sensor”.
✓
The lambda sensor has been checked and cleaned.
4.
Using a pipe wrench, unscrew
the DN 40 union nut (1).
5.
Remove the lambda sensor
(2) and the insulating washer
underneath it from the con-
nection nozzle (3) of the flue
gas pipe.
Figure 7/16 - Cleaning the lambda sensor
1
2
3
Important!
Steel bristles will damage the lambda sensor.
To clean the lambda sensor, use a fine brass brush instead of a steel
brush.
Important!
When reinstalling the lambda sensor, make sure its seal is intact.
Use a pipe wrench to tighten the union nut. Do not tighten the
lambda sensor excessively. Never tighten the lambda sensor by the
shaft body.