ADP200 • Quick installation guide - Specifications and connection
87
Description
Features
Type
Current differential
Input current
0 (4) mA to 20 mA
Input R
500 Ω
Resolution
12 Bits (11 + sign)
Precision
1% of full scale
Isolation
NO
AI-X
AI-X
-
+
AI-X
500
OP
(*)
(*) Select input V/I (V=OFF, I=ON)
●
Selection of Voltage/Current at analog inputs / output and Pressure sensor
In addition to programming the parameter (PAR 1602 - 1652 - 1898) the position of switches P3-P4-P5 on the I/O card
must also be checked.
P2 P3 P4
P5
OFF
ON
I
V
Jumper (I/O card)
Parameter combination
P2
AIS : Pressure sensor input
ON = I
OFF = V
1502
Analog inp 1 type
P3
AI1: Analog input
ON = I
OFF = V
1602
Analog inp 1X type
P4
AI2: Analog input
ON = I
OFF = V
1652
Analog inp 2X type
P5
AI2: Analog output
See figure
1898
Analog out 2X type
●
Analog output (AO)
Description
Features
Type
Single-ended in voltage
Output voltage
0 to 10V
Load
5 mA @ ± 10 V - R
l
= 2.2 kΩ
Resolution
12 Bits
Precision
1% of full scale
Isolation
NO
Description
Features
Type
Single-ended in current (only output 2)
Output current
0 (4) mA to 20 mA
R load
500 Ω
Resolution
12 Bits
Precision
1% of full scale