ADP200 • Quick installation guide - Specifications and connection
71
(1) Press the
E
key to proceed to the autotune procedure.
(2) Press the
E
key to start the autotune procedure.
(3) Enable the drive by connecting terminal 9 on the I/O card (Enable) to terminal 12 (+24 V). To abort this operation,
press the
ESC
key.
(4) Once the drive is enabled the autophase procedure starts. This may take a few minutes, depending on the type of
motor being used.
(5) At the end of the procedure the following screen is displayed. After opening the Enable contact, proceed to step 6.
Step 6 - Setting the maximum speed reference value
Setting the maximum speed reference value: this defines the maximum motor speed value (in rpm) that can be
reached with each single reference signal (analog or digital).
03 STARTUP WIZARD
Set max motor speed?
E=Yes
Down=Next
E
SEQ
SEQ . 01
PAR: 680
Full scale speed
2400
rpm
Def:
2000
E
SEQ
SEQ . 01
PAR: 680
Full scale speed
00000240
0
rpm
Def:
2000
▲
2401 rpm
▼
2399 rpm
E
After setting the speed, proceed to step 7.
Note!
The factory (default) setting depends on the size of the drive that is connected. These values refer to the ADP200-2110-...
Step 7 - Setting the ramps
Set the acceleration and deceleration times for the profile of ramp 0 :
03 STARTUP WIZARD
Set ramps ?
E=Yes
Down=Next
E
SEQ
SEQ . 01
PAR: 700
Acceleration time 0
11.00 s
Def:
10.00
E
SEQ
SEQ . 01
PAR: 700
Acceleration time 0
00001
1
.0 s
Def:
10.00
▲
12 s
▼
10 s
E
SEQ
SEQ . 02
PAR: 702
Deceleration time 0
10.00 s
Def:
10.00
E
SEQ
SEQ . 02
PAR: 702
Acceleration time 0
00001
0
.0 s
Def:
10.00
▲
11 s
▼
9 s
E
After setting the ramps, proceed to the next step.
Step 8 - Setting application parameters
Not used.
Press
keys.
Step 9 - Save parameters
To save the new parameter settings, so that they are maintained also after power-off, proceed as follows:
03 STARTUP WIZARD
Save parameters?
E=Yes
Down=Next
E
SEQ
SEQ . 01
PAR: 550
Save parameters?
Press E to execute
E
SEQ
SEQ . 01
PAR: 550
Save parameters?
Done
03 STARTUP WIZARD
End of sequence
Up=Back
Down=Exit
(1)
(2)
(3)
(4)
(1) Press the
E
key to start the save parameters procedure.
(2) Press "E" to confirm
(3) End of procedure