28
ADP200 • Quick installation guide - Specifications and connection
7.1 Power section
7.1.1 Cable cross-sections
Size
Terminals: L1 - L2 - L3 - BR - C1 - C - D - U - V - W
Maximum cable cross-section
(flexible conductor)
Minimum cable cross-section
(flexible conductor)
Recommended
stripping
Recommended
terminal
Tightening
torque (min)
(mm
2
)
AWG
(mm
2
)
AWG
(mm)
(mm)
(Nm)
2075
6
8
0.2
24
10
None / pin
0.7 ... 0.8
2110
6
8
0.2
24
10
None / pin
0.7 ... 0.8
3150
16
6
0.75
18
14
None / pin
1.7 ... 1.8
3185
16
6
0.75
18
14
None / pin
1.7 ... 1.8
3220
16
6
0.75
18
14
None / pin
1.7 ... 1.8
Terminals: L1 - L2 - L3 - BR1 - BR2 - C - D - U - V - W
4300
35
2
0.5
20
18
None / pin
2.4 ... 4.5
4370
35
2
0.5
20
18
None / pin
2.4 ... 4.5
4450
35
2
0.5
20
18
None / pin
2.4 ... 4.5
5550
95
(BR1/BR2=50)
4/0
(BR1/BR2=1/0)
10
4/0
23
(BR1/BR2=27)
None / pin
14
(BR1/BR2=10)
5750
95
4/0
10
4/0
23
None / pin
14
Note!
The power terminal strip is extractable on sizes 2075 ... 3220. The EM terminal strip is extractable on all mechanical sizes.
Size
Terminals: BR1 - BR2
Maximum cable cross-section
(flexible conductor)
Minimum cable cross-section
(flexible conductor)
Recommended
stripping
Recommended
terminal
Tightening
torque (min)
(mm
2
)
AWG
(mm
2
)
AWG
(mm)
(mm)
(Nm)
5S550 / 5S750
25
2
10
10
19
None
4.5
Sizes
Terminals: L1 - L2 - L3 - C - D - U - V - W
Cable cross-section
Lock screw diameter
Recommended
terminal
Tightening torque (min)
(mm
2
)
AWG
(mm)
(mm)
(Nm)
5S550 / 5S750
50
1/0
M10
Eyelet - Fork
25
Size
Terminals:
on structural work
Cable cross-section
Lock screw diameter
Recommended
terminal
Tightening torque (min)
(mm
2
)
AWG
(mm)
(mm)
(Nm)
3220
Same as the maximum cross-section used for the
power terminal strip
M5
Eyelet - Fork
6
4300
16
6
M6
Eyelet - Fork
10
4370
16
6
M6
Eyelet - Fork
10
4450
16
6
M6
Eyelet - Fork
10
5550
50
1/0
M6
Eyelet - Fork
10
5750
50
1/0
M6
Eyelet - Fork
10
5S550 / 5S750
50
1/0
M10
Eyelet - Fork
25
Note!
The power terminal strip is extractable on sizes 2055 ... 3110.
Note!
The minimum cross-section for both ground connections must comply with EN61800-5-1 prescriptions. Always ground both points on structural steel.