ADP200 • Quick installation guide - Specifications and connection
51
•
Modifying Enum values
When you press
Enter
on an Enum value, the first digit on the right flashes.
Use the arrow keys to scroll all the enum values of that parameter cyclically.
Press
Enter
again to accept the value.
Press
Prg
to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 4.15 – DRIVE CONFIG, PAR 578
Language select
(default = [0]
English
)
04.
88.
Enter
(x14)
05
.
78
.
Enter
00. 8
0
.
Enter
00
.
0
0
.
00
.
0
1
.
Enter
00. 8
1
.
•
Modifying Link values
When you press
Enter
on a Link value, the first digit on the right flashes.
Use the arrow keys to scroll all the links in the list associated with that parameter cyclically.
Press
Enter
again to accept the value.
Press
Prg
to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 13 – DIGITAL OUTPUTS, PAR 1410
Dig output 1X src
(default = [6000]
Null
)
13.
88.
Enter
14
.
10
.
Enter
60
.
00
.
Enter
60
.
00
.
60
.
02
.
Enter
60
.
02
.
•
Modifying On-Off values
Boolean values are displayed with the words On and Off.
When you press
Enter
, the first digit on the right flashes.
Use the up and down arrow keys to change the value cyclically from On to Off.
Press
Enter
again to accept the value.
Press
Prg
to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 4.14 – DRIVE CONFIG , PAR 576
Display backlight
(default = [0]
OFF
)
04.
88.
Enter
(x13)
8
5
.
76
.
Enter
8
o
.
FF
.
Enter
8
o
.
F
F
.
88.
on
.
8.2.4 Error messages when modifying a parameter
When accepting a value, if you hold
Enter down
or press
Enter on
the last digit, an error message may be displayed:
RO
Read only parameter, if
Enter
is pressed on a read only parameter
ORNG
Value outside range
DRVE
Drive enabled, if you are trying to modify a parameter than cannot be modified with the drive enabled
ERR
Other errors
Press
Prg
to clear the error message.
8.2.5 Displaying and closing Messages
Note !
Some messages may be displayed on the integrated keypad at start-up or during operation. The list of messages is provided in chapter "10.3 Messages" .
Sub-codes are not shown on the integrated keypad.
Press
Prg
to exit a message if it does not close automatically
.
8.2.6 Displaying and resetting Alarms
Note !
The alarms are shown on the display of the integrated keypad with the abbreviated text shown in brackets "[XXX]" in chapter "10.1 Alarms" on page 88 .
Active alarms are displayed by a flashing indicator.