ADP200 • Quick installation guide - Specifications and connection
31
7.1.4 Block diagram of power section
This type is equipped with an EMI input filter (models ADP200.-...-F-...), an AC/DC converter, a system for pre-loading
DC capacitors, a DC/AC converter, a power supply unit and an integrated braking unit (except ADP200-5750 size, see
below).
A specific external resistor must be connected to perform the braking function.
The connection of the external braking resistor depends on the drive size:
•
(1) connect the resistor between terminals C and BR
•
(2) connect the resistor between terminals BR1 and BR2.
•
(3) an optional external BUy braking unit can be used and connected to terminals C and D. Refer to the BUy hand-
book for further information.
EMI
L1
L2
L3
Emi filter & converter
DC link
Inverter
Rprc
EMI
L1
L2
L3
Emi filter & converter
DC link
Inverter
Rprc
C1
C
BR
D
D
C
BR1 BR2
U
V
W
U
V
W
ADP200-2075...3220
ADP200-4300...5550
ADP200-5S550
ADP200-5S750
EMI
L1
L2
L3
Emi filter & converter
DC link
Inverter
Rprc
D
C
U
V
W
ADP200-5750
1
2
3
Filter (*)
Filter (*)
Filter (*)
(*) ADP200.-...-F-.. models
(*) ADP200.-...-F-.. models
(*) ADP200.-...-F-.. models
7.1.5 Internal EMC filter (standard)
In compliance with EN61800-3. Conducted emission C2 up to 11kW and C3 with “F” configuration.
(External filter available for standard version, no filter inside).