ADP200 • Quick installation guide - Specifications and connection
55
8.3.3 Scanning of the parameters
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 REFERENCES
01 MONITOR
01.01
PAR: 250
Output current
0.00
A
0%
01 MONITOR
01.24
PAR: 1400
Digital output X mon
00000000000000
01 MONITOR
01.02
PAR: 252
Output voltage
0 V
0%
8.3.4 List of the last parameters modified
Pressing the
CUST
key, a list containing the last 10 parameters modified is accessed. One parameter is displayed at a
time and the list can be scrolled using the ▲ and ▼ keys.
To exit this list, press the ► key.
8.3.5
Parameter modification
To enter parameter modification mode, press the
E
key when the parameter to be modified is displayed.
To save the value of the parameter, following modification, press the
E
key again.
Note!
To save permanently,
see paragraph 8.4
.
To exit modification mode without saving the value, press the
ESC
key.
The operations to be carried out to modify the value depend on the type of the parameter, as described below.
Note!
For further information about the type of parameters displayed,
see paragraph 8.2.2
.
●
Numeric parameters
16 MOTOR DATA
17 ENCODER CONFIG
18 SPEED REG GAINS
19 REGULATOR PARAM
20 TORQUE CONFIG
16
MOTOR DATA
16.01
PAR: 2000
Rated voltage
175
V
Def: 400
E
16
MOTOR DATA
16.01
PAR: 2000
Rated voltage
00000017
5
v
Def:
400
When
E
is pressed to access modification mode, the cursor is activated on the digit corresponding to the unit.
Using the ◄ and ► keys, the cursor can be moved to all the digits, including trailing zeros that are normally not
displayed.
With the ▲ and ▼ keys, the digit under the cursor is increased or decreased.
Press
E
to confirm the modification or
ESC
to cancel.
●
Binary parameters (BIT type)
The parameter may assume only two states which are indicated as
On
-
Off
or 0-1.
13 DIGITAL OUTPUTS
14 ANALOG INPUTS
15 ANALOG OUTPUTS
16 MOTOR DATA
17 ENCODER CONFIG
x9
13 DIGITAL OUTPUTS
13.10
PAR: 1430
Dig out 1X inversion
OFF
E
13 DIGITAL OUTPUTS
13.10
PAR: 1430
Dig out 1X inversion
OFF
13 DIGITAL OUTPUTS
13.10
PAR: 1430
Dig out 1X inversion
ON
Press
E
to activate modification mode. The entire line is displayed in reverse. Use the ▲ and ▼ keys to move from one
state to another. Press
E
to confirm the modification or
ESC
to cancel.