ADP200 • Quick installation guide - Specifications and connection
53
8.2.8 Motor self-tuning
From Startup wizard
Run
Autotune still
to enable motor self-tuning.
The following warning messages are displayed at the start and end of Self-tuning:
Operations displayed on the optional keypad
Operations displayed on the integrated keypad
Close Enable input
C EN
Open Enable input
O EN
When the self-tuning procedure is executed its progress is displayed. In this phase the first digit on the right indicates
the progress of the procedure by rotating the external segments of the display.
If an error occurs, the word
Er
is displayed with the error code. Press
Prg
to exit the error.
Note !
For further information see chapter "9.2 Startup wizard for brushless motors (with the optional keypad)