ADP200 • Quick installation guide - Specifications and connection
41
7.4 Serial interface (PC connector)
5
1
9
6
PC
PIN
Function
I/O
Elect. Interface
O = Output, I/O = Input/ Output
1
-
-
-
2
-
-
-
3
A
I/O
RS485
4
EQP
-
RS485
5
0V (Ground)
-
Supply
6
+5V
-
Supply
7
B
I/O
RS485
8
0V (Ground)
-
Supply
9
DIR
O
RS485
The ADP200 drive is provided with a port as standard (9-pin D-SUB receptacle connector) for connection of the RS485
serial line used for drive-PC point-to-point or multipoint communication (with the GF-eXpress configuration software).
Note!
The port
is not galvanically isolated
. The
OPT-RS485-ADP option must be used If galvanic separation is required.
7.4.1 Drive/
RS485
port point-to-point connection
1
2
3
4
5
9
8
7
6
TxA/RxA
TxB/RxB
PE
+5 V
RS485
Reserved
RS485
EQP
Figure 7.5.1: Serial connection (not isolated)
A twin-pair consisting of two symmetrical conductors, spiral wound with a common shield plus the bonding connection
cable, connected as shown in the figure, must be used for connection. The transmission speed is 38.4 kBaud.
For connection of the RS485 serial line to the PC, see the figure below.
RS485
RS232
PCI-COM
(S560T)
RS232
USB
USB RS232 converter
(S5A20)
PC with RS232 port
PC with USB port
RS485
RS232
PCI-COM
(S560T)
Shielded cable with connectors,
(8S864C)
5 mt
Shielded cable with
connectors,
(8S864C)
5 mt
Kit (S50T6) = Shielded cable 5 mt + PCI-COM
RS485
RS485
C)
D)
Industrial PC
(with RS485)
Shielded cable with connectors,
5 mt (8S864C)
RS485
A)
RS485
RS232
PCI-COM
(S560T)
PC with RS232 port
Shielded cable with connectors,
(8S864C)
5 mt
RS485
B)
Optional
PC-OPT-ADP
(S5L85)
Figure 7.5.2: RS485 connection to the PC