6-16
6-3 Detailed Description of Parameters (Registers)
4) +OT detection disable (bit 6)
Selects enabling/disabling of the processing under +OT signal input.
When set to “0”: Enables the stop operationunder the +OT signal.
When set to “1”: Disables the stop operation under the +OT signal.
Points of use:
· When +OT detection is enabled, error treatment by +OT detection is performed if +OT input signal is turned
OFF (NC contact signal).
· When +OT detection is disabled, the +OT signal can be used as a general-purpose input signal.
5) -OT detection disable (bit 7)
Selects enabling/disabling of the processing under -OT signal input.
When set to “0”: Enables the stop operation under the -OT signal.
When set to “1”: Disables the stop operation under the -OT signal.
Points of use:
· When -OT detection is enabled, error treatment by -OT detection is performed if -OT input signal is turned
OFF (NC contact signal).
· When -OT detection is disabled, the -OT signal can be used as a general-purpose input signal.
6) Automatic acceleration/deceleration disable (bit 8)
Selects enabling/disabling of the processing for automatic acceleration/deceleration.
When set to “0”: Enables the processing for automatic acceleration/deceleration.
When set to “1”: Disables the processing for automatic acceleration/deceleration.
Points of use:
· When automatic acceleration/deceleration processing is disabled, the deceleration point register is forcibly
cleared to zero. Therefore, automatic deceleration point calculation is disabled. Function of the following
registers is also disabled:
Base frequency register (forcibly cleared to zero)
Deceleration point register
Acceleration/deceleration register 1 and 2
· In the position command mode, this signal is forcibly set to “1” by this module.
(Automatic acceleration/deceleration is disabled.)
Содержание micrex-sx NP1F-MP1
Страница 1: ...FEH214a series USER S MANUAL PULSE TRAIN POSITIONING CONTROL COMBINED MODULE...
Страница 28: ...3 10 3 4 Dimensions 3 4 1 NP1F MP1 for 1 axis 3 4 2 NP1F MP2 for 2 axes 90 46 5 75 35 105...
Страница 29: ...3 11 3 4 Dimensions 3 4 3 NP2F LEV Signal converter 95 47 2 10 29 8 39 8 85 95 40 36 6...
Страница 223: ...Section 8 Troubleshooting Page 8 1 LED Indication 8 1 8 2 Error Indication 8 2...