7-9
Frequency
Target command frequency
Acceleration/deceleration time t
≥
5.2ms (an integrated multiple of 2.6ms) or
Acceleration/deceleration time t
≥
84ms (an integrated multiple of 42ms)
t
Time
t
Points of use:
· To shorten acceleration/deceleration time, decrease the set value of the speed multiplication register and
increase the target command frequency.
· Acceleration/deceleration time is the time until the target frequency is reached from speed 0. Therefore, the
acceleration time from 0 to 250kHz becomes as follows:
20-bit width: when target command frequency is set to 250kHz,
Minimum acceleration time min = 84ms
20-bit width: when target command frequency is set to 1041667kHz,
Minimum acceleration time min = 84ms x (250kHz / 1041667kHz)
= 20ms
· When target command frequency is increased, the resolution of the pulse command frequency becomes rough.
7-3 Functions of Pulse Generation Mode