5-3 I/O Area of NP1F-MP2
)
d
n
e
g
n
i
n
o
i
t
i
s
o
P
:
e
m
a
n
l
a
n
g
i
S
(
2
t
i
B
<Description>
• In the pulse generation mode, this signal becomes “1” when the positioning operation has ended. This signal also
becomes “1” when command pulse output is stopped or when the near-zero signal is “1” and the start command
signal is “0.”
After the positioning end signal becomes “1,” this signal continues to be “1” even when the near-zero signal
changes.
Outputting command pulse
(internal signal)
Near-zero
(PC <== MP2)
Positioning end
(PC <== MP2)
“1”
“1”
“1”
“0”
“1”
Positioning end signal is “0”
because the command pulse
is being output.
Positioning end signal is “1”
because the positioning end
signal has been detected.
Precautions:
This signal becomes “0” while the start command is “1.”
• In the position command mode, the positioning end signal becomes “0” while the start command is “1.”
When the start command becomes “0,” pulse output is immediately stopped.
After this, the positioning end signal becomes “1” when near-zero signal becomes “1.”
“1”
Positioning end
(PC <== MP2)
“1”
Near-zero
(PC <== MP2)
“1”
Start command
(PC == > MP2)
Operates according to
position data.
Содержание micrex-sx NP1F-MP1
Страница 1: ...FEH214a series USER S MANUAL PULSE TRAIN POSITIONING CONTROL COMBINED MODULE...
Страница 28: ...3 10 3 4 Dimensions 3 4 1 NP1F MP1 for 1 axis 3 4 2 NP1F MP2 for 2 axes 90 46 5 75 35 105...
Страница 29: ...3 11 3 4 Dimensions 3 4 3 NP2F LEV Signal converter 95 47 2 10 29 8 39 8 85 95 40 36 6...
Страница 223: ...Section 8 Troubleshooting Page 8 1 LED Indication 8 1 8 2 Error Indication 8 2...