8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
177
Sub-index
01
h
Description
ip_data_position
Data Type
INT32
Access
rw
PDO Mapping
yes
Units
position units
Value Range
--
Default Value
--
Sub-index
02
h
Description
ip_data_controlword
Data Type
UINT8
Access
rw
PDO Mapping
yes
Units
--
Value Range
0, 1
Default Value
0
Value
ip_data_position actual
0
Absolute position
1
Relative distance
The internal data transfer takes place with write access to
subindex 1. If subindex 2 should also be used, it must be written
before subindex 1.
Object 60C2
h
: interpolation_time_period
The synchronisation interval can be set via the object record
interpolation_time_period
.
Via
ip_time_index
, the unit (ms or 1/10 ms) of the interval is established, which is
parameterised via
ip_time_units
. To achieve synchronisation, the complete controller
cascade (current, speed and position controller) is synchronised up to the external cycle.
A change in the synchronisation interval is therefore effective only after a reset. Therefore,
if the interpolation interval is to be changed via the CAN bus, the parameter set must be
saved (see chapter 6.1) and a reset performed (see chapter 5.6) so that the new
synchronisation interval becomes effective. The synchronisation interval must be
maintained exactly.