6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
95
Access
rw
PDO Mapping
yes
Units
position units
Value Range
--
Default Value
1820 (1820/65536 U = 10°)
Object 6068
h
: position_window_time
If the actual position of the drive is located within the positioning window
(
position_window
) for as long as defined in this object, the related bit 10
target_reached
is set in the
statusword
.
Index
6068
h
Name
position_window_time
Object code
VAR
Data Type
UINT16
Access
rw
PDO Mapping
yes
Units
ms
Value Range
--
Default Value
0
Object 6510
h
_ 22
h
: position_error_switch_off_limit
In the object
position_error_switch_off_limit
, the maximum permissible deviation
between the target and actual position can be entered. If exceeded, in contrast to the
above following error message, the final stage is switched off immediately and an error
triggered. The motor thus spins out without braking (unless a holding brake is present).
Index
6510
h
Name
drive_data
Object code
RECORD
No. of Elements 51
Sub-index
22
h
Description
position_error_switch_off_limit
Data Type
UINT32
Access
rw
PDO Mapping
no
Units
position units
Value Range
0 … 2
32
- 1
Default Value
0
Содержание CMMP Series